Power Supply Installation
Power-Supply Module Installation
Low-voltage DC Power-Supply Module
Connect the wires to the terminals labeled Lo.
High-voltage DC Power-Supply Module
Connect the wires to the terminals labeled Hi.
Note:
Ensure that you cannot see any wire lead. Only wire with insulation should extend from the terminal screw.
Figure 33
Connecting the Wires to the Low-Voltage DC Power (PSU2)
8.
Torque the captive screws (above the wires) to 8.5 in-lb (± 0.5 in-lb).
9.
Complete the power connection:
AC Power Connection
Connect the other end of the line wire (the one connected to L) to the line terminal on the AC-power source, and
connect the other end of the neutral wire (the one connected to N) to the neutral terminal on the AC power source.
DC Power Connection
Connect the other end of the positive wire (the one connected to "+") to the positive terminal on the DC-power
source, and connect the other end of the negative wire (the one connected to "–") to the negative terminal on the
DC power source.
Note:
Ensure that you cannot see any wire lead. Only wire with insulation should extend from the terminal screw.
If you have two power supplies, repeat steps 1 through 10.
10.
Close the power-input terminal cover.
11.
Use a ratcheting torque screwdriver to torque the screw to 7 in-lb (± 1 in-lb).
12.
Turn on the power at the AC or DC circuit.
13.
Verify that the PSU1 or PSU2 LED on the switch and PSU OK LED on the power-supply module are green.
See the switch software guide for information on how to configure the power supply settings.