Thermal Restrictions - Dell EMC PowerEdge R940 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge R940:
Table of Contents

Advertisement

Thermal restrictions

Following table lists the configuration required for efficient cooling:
Table 32. Thermal restriction for efficient cooling
Configuration
Number of
processors
Eight 2.5 inch
2
hard drive
system
4
Twenty four 2.5
2
inch hard drive
system
4
Table 33. NIC card slot restrictions
Configuration
Eight 2.5-inch hard drive system
Twenty four 2.5-inch hard drive system
32
Technical specifications
Heatsink
Two heat sinks for CPU <
165W
Two heat sinks for CPU ≥ 165
W
Four standard heat sinks for
CPU < 165 W
Four heat sinks CPU ≥ 165 W
Two standard heat sinks for
CPU < 165W
Two heat sinks for CPU ≥ 165
W
Four standard heat sinks for
CPU < 165 W
Four heat sinks for CPU ≥ 165
W
Slot restriction
Slots 1, 5, and 6 do not support NIC
cards
Slots 1, 5, and 6 do not support NIC
cards
Processor blank
DIMM
blanks
Not required
12
Not required
24
Not required
12
Not required
24
Ambient restriction
35°C
35°C
Fresh air
Fan
Yes
eight standard
fans
No
Yes
eight standard
fans
No
Yes
eight standard
fans
No
Yes
eight standard
fans
No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents