Toshiba HWS-P804XWHM3-E1(TR) Service Manual page 134

Air to water heat pump
Table of Contents

Advertisement

13. Display Function of Set Temperature and Other Settings
Sensor temperature display calling
<Details>
This function calls the service monitor mode from the remote controller
to show the data of the remote controller, the hydro unit, and outdoor
unit.
<Procedure>
1
Press the TEST
for 4 seconds or longer to call the service monitor mode.
The service monitor lights up, and the temperature of CODE No.
"00" displays at first.
2
Press the TEMP.
to change the item code to one to be monitored.
The following table shows the item codes.
Item code
00
Control temperature (Hot water cylinder), (TTW)
01
Control temperature (Zone1), (TWI)
02
Control temperature (Zone2), (TFI)
03
Remote controller sensor temperature
04
Condensed temperature (TC)
06
Water inlet temperature (TWI)
07
Water outlet temperature (TWO)
08
Water heater outlet temperature (THO)
09
Floor inlet temperature (TFI)
0A
Hot water cylinder temperature (TTW)
0B
Mixing valve position
0E
Low pressure (Ps)
Item code
60
Heat exchange temperature (TE)
61
Outside air temperature (TO)
62
Discharge temperature (TD)
63
Suction temperature (TS)
65
Heat sink temperature (THS)
6A
Current × 10
6D
Heat exchanger coil temperature (TL)
70
Compressor operation Hz
72
Number of revolutions of outdoor fan (lower)
73
Number of revolutions of outdoor fan (upper)
74
Outdoor PMV position × 1/10
7A
Discharge pressure (PD)
Item code
F0
Micro computer energized accumulation time
F1
Hot water compressor ON accumulation time
F2
Cooling compressor ON accumulation time
F3
Heating compressor ON accumulation time
F4
Built-in circulation pump operation accumulation time
F5
Hot water cylinder heater operation accumulation time × 100 h
F6
Backup heater operation accumulation time
F7
Booster heater operation accumulation time
3
Pressing the TEST
AMP Air Conditioning
and CL
buttons at the same time
(See display
)
button for temperature setting
Data name
Data name
Data name
button returns to the usual display.
2
Unit
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
step
×10 kPa
Unit
°C
°C
°C
°C
°C
A
°C
Hz
rpm
rpm
pls
×10 kPa
Unit
× 100 h
× 100 h
× 100 h
× 100 h
× 100 h
× 100 h
× 100 h
133