4. Auto Curve Setting
FC code setting can make flexible Auto-Curve settings.
<Preparation>
1
Press the TEST
buttons at the same time for 4 seconds or longer.
(See display
(Make sure that no operation is in progress.)
2
Specify an item code (FC) from among 29 to 2F with the
TEMP.
3
Set data with the TIME
4
Press the SET
confirmed)
5
2
Repeat
through
6
Pressing the TEST
stop state.
<ZONE1>
• An operation starts at the set temperature of straight -line approximation for the following: water temperature A °C with the outside
temperatureT0 °C, B °C with T1 °C, C °C with T2 °C, D °C with T3 °C, and E °C with 20 °C.
TSC_F (°C)
A(40)
B(35)
C(30)
D(25)
E(20)
T0
(-20)
<ZONE2>
• Set temperature of the ZONE2 can be selected from two methods (FC_A2). One is a percentage of ZONE1, the other is a fixed value.
FC_A2 = "0" : Percentage method that is set by FC_31.
FC_A2 = "1" : Fixed value method that is set by FC_A3, A4 and A5.
However, it is automatically controlled the set temperature of ZONE1 to be the ZONE2 or more.
TSC_F(°C)
A(40)
B
(35)
C
(30)
D
(25)
E
(20)
(-20)
Auto-Curve in ZONE2 shows 80% (FC) of that of ZONE1,the
water temperature setting does not fall below 20 °C.
Related FC
FC No.
A2
The choice of how to set ZONE2
A3
Setting temperature A' at T0
A4
Setting temperature B' at T1
A5
Setting temperature E' at 20 °C
31
Auto-Curve ratio of ZONE2
AMP Air Conditioning
and SET
and SELECT
)
button for temperature setting.
button for timer setting.
button. (If
lights, the status is
4
for each item.
button moves the unit to the normal
± 5K adjustable (FC 27)
T1
T2=0
T3
20 TO
(°C)
(-10)
(10)
FC_A2=0 Percentage method
ZONE 1
ZONE 2
80 % (FC_31) of ZONE1
T0
T1
T2=0
T3
20 TO (°C)
(-10)
(10)
Setting item
Related FC
FC No.
2C
Setting temperature A at T0
2D
Setting temperature B at T1
2E
Setting temperature C at T2(= 0
2F
Setting temperature D at T3
30
Setting temperature E at 20
A1
Outside temperature T0
29
Outside temperature T1
2B
Outside temperature T3
27
Set temperature shift with heating set to auto
FC_A2=1 Fixed value method
TSC_F(°C)
A'(40)
B'
(35)
E'
(20)
T0
(-20)
The ZONE2 set temperature A' °C with the outside
temperature T0 °C, B' °C with T1 °C, E' °C with 20 °C.
Default
range
0
0 or 1
40
20~60 °C
35
20~60 °C
20
20~60 °C
80
0~100%
125
www.ampair.co.uk | sales@ampair.co.uk
2
3
4
6
Setting item
Default
40
35
°C
)
30
25
°C
20
-20
-10
10
0
T1
20 TO (°C)
(-10)
1
range
20~60 °C
20~60 °C
20~60 °C
20~60 °C
20~60 °C
-30~-20 °C
-15~0 °C
0~15 °C
-5 to 5K