Programming Troubleshooting
Symptom
Lock does not respond –
door is open and
accessible.
Lock does not respond –
door is locked and
inaccessible.
Unit is on for a while then
shows no reaction. Lights
dim.
Unit chimes to indicate
code acceptance, but the
door will not open.
Unit operates to allow
access, but will not
automatically re-lock.
PIN codes will not register.
Upon entering a
and pressing
unit displays "invalid code"
error or lock times out with-
out responding.
Upon entering a
and pressing the
the red padlock icon appears
and there are different tones.
The unit operates, but it
makes no sound.
The unit responds
"Low Battery"
Upon entering a
and pressing the
the unit responds "Wrong
number of digits".
* When batteries are replaced, Network Module locks have a real time clock that will be set
through the User Interface ( ); it is recommended to verify correct date and time
particularly those locks operating under Daylight Saving Time (
** Network Module locks only
Touchscreen becomes active when pressed w/whole hand.
•
Use a larger area of the hand or fingers and verify contact
with at least 3 areas.
•
If touchscreen numbers are visible, check to see if they
respond when pressed.
Check batteries are installed and oriented correctly (polarity)
•
in the battery case.
Check batteries are in good condition; replace batteries*
•
if discharged.
Check to see if touchscreen harness is fully connected
•
and not pinched.
Batteries may be completely discharged.
•
Apply 9V battery to terminals below the touchscreen for
•
backup power option.
•
Batteries do not have enough power. Replace batteries*.
Check the door gaps for any foreign objects between door
•
and frame.
Check that the wire harness is firmly connected to the
•
•
Check to see if Auto Re-lock Mode is enabled.
Disable Auto Re-lock Mode to lock the door (automatically).
•
If low battery indicator is lit (see below), change batteries *.
•
PIN codes must consist of 4 to 8 digits to register.
•
•
The same
Registration/management of
•
authority of the Master Code, which is set first.
•
Contact the Master user.
User codes must be entered within 5 seconds (while
•
touchscreen is active) or process will have to be restarted.
Check
•
PIN
code
•
Lockout Mode is enabled.
key, the
Only the Master can enable/disable Lockout Mode.
•
•
Contact the Master user.
PIN
code
•
Check to see if the lock is set to Lockout Mode.
key,
•
Setting/managing Lockout Mode is done through
Master Code only. Contact the Master user.
•
Check to see if Silent Mode is enabled (see Feature #4).
•
This is the alert to replace the batteries. Replace all four
(4) batteries* with new
PIN
code
key,
•
The digits entered were incorrect or incomplete. Re-enter
the correct code followed by the check
UI
P/N
YRL KFTSINSTL FUL
-
Suggested Action
PIN
code cannot be used for multiple users.
PIN
codes is set by the
or gear
cannot be used as part of the
AA
Alkaline batteries.
DST
18
-
Rev E
PCB
.
PIN
code.
key.
).