Siemens MICROMASTER 440 Quick Start Manual page 49

Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Parameter
Parameter Description
Number
P0640[0]
Enter Motor Overload Factor
This defines the limit of the maximum output current as a %
of the rated motor current (P0305). This parameter is set,
using P0205 for constant torque, to 150 %, and for variable
torque, to 110 %.
P0700[0]
Select of Command Source (Start/Stop)*
0
1
2
4
5
6
NOTE
Changing the setting of P0700 will result in all Digital
inputs and outputs being reset to their defaults for that
setting. See Parameter List for full details.
P1000[0]
Select of Frequency Setpoint Source *
1
2
3
4
5
6
7
P1080[0]
Set Min. Frequency
Enters the lowest motor frequency with which the motor
operates independently of the frequency setpoint. The
value which is set here applies for both directions of
rotation.
P1082[0]
Set Max. Frequency
Enters the maximum frequency to which, for example, the
motor is limited independently of the frequency setpoint.
The value which is set here applies for both directions of
rotation.
NOTE
You should check with your motor manufacturer if you
intend to operate above nominal motor frequency.
Lifetime and/or safety could be compromised if you go
too fast.
P1120[0]
Set Ramp-Up Time
Enters the time with which, for example, the motor should
accelerate from standstill up to the maximum frequency
P1082. If the ramp-up time is set too low, this may result in
alarm A0501 (current limit active) or the drive tripping out
with fault F0001 (overcurrent).
MICROMASTER 440
6SE6400-5GA00-0BP0
Resets the digital I/O to the factory default setting
BOP (drive inverter keypad)
Terminal strip (factory default setting)
USS on BOP link (RS232)
USS on COM link (via control terminals 29 and 30)
CB on COM link (CB = communications module)
Motorized potentiometer setpoint (MOP setpoint)
Analog input (factory default setting)
Fixed frequency setpoint
USS on BOP link
USS on COM link (control terminals 29 and 30)
CB on COM link (CB = communications module)
Analog input 2
Quick Start Guide
Issue 08/03
Suggested
User
Setting
Setting
150
2
2
0
60
10
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mm440