4-4 Data Logger

The data logger function can save 1,600-point measuring
data.
The data logger procedures are following :
a) Press the " REC. Button " ( 3-5, Fig. 1 ) once to start
the Data record function and there will be a " REC. "
symbol on the display.
b) Auto Data Logger ( Sampling time should select
to 1, 2, 5, 10, 30, 60, 600, 1800 or 3600 seconds )
Press the " Logger button " ( 3-6, Fig. 1 ) once to start
the Data Logger function. The " REC " symbol will flash
per 1.5 second when save the data into the memory.
Now the Date Logger function is executed.
Manual Data Logger ( Sampling time should set
to 0 second )
Press the " Logger Button " ( 3-6, Fig. 1 ) once will
save the data one time into the memory, at the
same time the symbol " REC " will flash once and
the beeper will sound.
Memory full
When execute the data logger function, if the upper
display show " FULL " with flashing, it indicate the
memory data already over 1,600 no. and the
memory is full.