Summary of Contents for Lutron Electronics LM-8010
Page 1
CMM, CFM Anemometer, Hygrometer Light Meter, Thermometer Model : LM-8010 Your purchase of this METER marks a step forward for you into the field precision measurement. Although this METER is a complex and delicate instrument, its durable structure will allow...
1. FEATURES * 5 in 1 professional measuring instrument: Anemometer, Air flow, Hygrometer, Thermometer, and Light meter. * Tiny bone shape with lightweight and small size case design are suitable for handling with one hand. * Wristlet design provides extra protection to the instrument especially for user one hand operation.
2. SPECIFICATIONS 2-1 General Specifications Display 8 mm LCD display Measurement Anemometer, Humidity, Temperature, Light, Air flow ( CFM/CMM ). Operating Max. 80% RH. Humidity Operating 0 to 50° C (32 to 122° F) Temperature Over Input Indication of "- - - - " Display Power Supply 006P DC 9V battery (Heavy duty type)
Page 5
2-2 Electrical Specification ( 23 ± 5 ℃ Measurement Range Resolution Air velocity ft/min 80 to 5,910 ft/min 1 ft/min 0.4 to 30.0 m/s 0.1 m/s km/h 1.4 to 108.0 km/h 0.1 km/h 0.9 to 67.0 mile/h 0.1 MPH knots 0.8 to 58.3 knots 0.1 knots Temperature...
Page 6
Measurement Range Accuracy Air velocity 80 to 5,910 ft/min 0.4 to 30.0 m/s 20 m/s : ± 3% F.S. ≦ 1.4 to 108.0 km/h > 20 m/s : ± 4% F.S. 0.9 to 67.0 mile/h 0.8 to 58.3 knots 32 to 122 ℉ ±...
4. MEASURING PROCEDURE 4-1 Air Velocity Measurement 1) Power on the instrument by pressing the " ON Button " ( 3-1, Fig. 1 ). 2) Select the Anemometer function by pressing " Function Button " ( 3-6, Fig. 1 ). 3) Press the "...
* The temperature difference between thermocouple probe and thermometer will cause an inaccurate measuring result. Therefore, for the best measuring and accuracy performance, whenever change a probe or plug a new probe, thermal equivalent between probe plug and meter's input socket is a necessary condition. Thermal equivalent procedure may take few minutes and apply only when the probe has been exposed to an ambient temperature different from the meter.
Zero Offset Adjustment of Light Function : * For best results zero the light sensor prior to use in a dark environment. Placing the light sensor end of the meter under a desktop or flat surface so as to block any light can accomplish this.
* For the CMM measurement, the area size is " meter square ", the lower display will show " m-2 ". For the CMM, the area setting size is from 0.001 to 30.000 meter square. * For the CFM measurement, the area size is " feet square ", the lower display will show "...
2) With the REC symbol on the display : (a) Press the " REC Button " ( 3-3, Fig. 1 ) once and the " Max " symbol along with the maximum value will appear on the display. (b) Press the " REC Button " again, the " Min " symbol along with the minimum value will appear on the display.
* Measuring Range : -50 to 400 ℃ * surface Temp. ( -50 to 752 ℉ probe. * Size : Temp. sensing head - 15 mm Dia. Carrying case Probe length - 12 mm. CA-52A * High quality carrying case with sash. 0701-LM-8010...