Model : LM-8010
OPERATION MANUAL
Your purchase of this
METER marks a step
forward for you into the
field
of
measurement.
Although this METER is
a complex and delicate
instrument, its durable
structure
will
many years of use if
p r o p e r
o p e r a t i n g
t e c h n i q u e s
developed. Please read
t h e
f o l l o w i n g
instructions
and always keep this
manual
within
reach.
precision
allow
a r e
carefully
easy

Advertisement

Table of Contents
loading

Summary of Contents for Lutron Electronics LM-8010

  • Page 1 CMM, CFM Anemometer, Hygrometer Light Meter, Thermometer Model : LM-8010 Your purchase of this METER marks a step forward for you into the field precision measurement. Although this METER is a complex and delicate instrument, its durable structure will allow...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES..............1 2. SPECIFICATIONS............2 3. FRONT PANEL DESCRIPTION........5 3-1 ON/ESC Button............5 3-2 Hold Button............5 3-3 REC/Enter Button..........5 3-4 Unit/Zero/ ( CFM/CMM ) Button......5 / / , Lux/Ft-cd, Area-Set Button....℃ ℉ ▲ 3-6 Function/ Button..........
  • Page 3: Features

    1. FEATURES * 5 in 1 professional measuring instrument: Anemometer, Air flow, Hygrometer, Thermometer, and Light meter. * Tiny bone shape with lightweight and small size case design are suitable for handling with one hand. * Wristlet design provides extra protection to the instrument especially for user one hand operation.
  • Page 4: Specifications

    2. SPECIFICATIONS 2-1 General Specifications Display 8 mm LCD display Measurement Anemometer, Humidity, Temperature, Light, Air flow ( CFM/CMM ). Operating Max. 80% RH. Humidity Operating 0 to 50° C (32 to 122° F) Temperature Over Input Indication of "- - - - " Display Power Supply 006P DC 9V battery (Heavy duty type)
  • Page 5 2-2 Electrical Specification ( 23 ± 5 ℃ Measurement Range Resolution Air velocity ft/min 80 to 5,910 ft/min 1 ft/min 0.4 to 30.0 m/s 0.1 m/s km/h 1.4 to 108.0 km/h 0.1 km/h 0.9 to 67.0 mile/h 0.1 MPH knots 0.8 to 58.3 knots 0.1 knots Temperature...
  • Page 6 Measurement Range Accuracy Air velocity 80 to 5,910 ft/min 0.4 to 30.0 m/s 20 m/s : ± 3% F.S. ≦ 1.4 to 108.0 km/h > 20 m/s : ± 4% F.S. 0.9 to 67.0 mile/h 0.8 to 58.3 knots 32 to 122 ℉ ±...
  • Page 7: Front Panel Description

    3. FRONT PANEL DESCRIPTION Fig. 1 3-1 ON/ESC Button 3-6 Function/ Button ▼ 3-2 Hold Button 3-7 Anemometer Sensor 3-3 REC/Enter Button 3-8 Thermocouple Input Socket 3-4 Unit/Zero/ 3-9 Humidity Sensor ( CFM/CMM ) Button. 3-10 Light Sensor 3-11 LCD display ℃...
  • Page 8: Measuring Procedures

    4. MEASURING PROCEDURE 4-1 Air Velocity Measurement 1) Power on the instrument by pressing the " ON Button " ( 3-1, Fig. 1 ). 2) Select the Anemometer function by pressing " Function Button " ( 3-6, Fig. 1 ). 3) Press the "...
  • Page 9: Relative Humidity Measurement

    * The temperature difference between thermocouple probe and thermometer will cause an inaccurate measuring result. Therefore, for the best measuring and accuracy performance, whenever change a probe or plug a new probe, thermal equivalent between probe plug and meter's input socket is a necessary condition. Thermal equivalent procedure may take few minutes and apply only when the probe has been exposed to an ambient temperature different from the meter.
  • Page 10: Air Flow (Cfm. Cmm) Measurement

    Zero Offset Adjustment of Light Function : * For best results zero the light sensor prior to use in a dark environment. Placing the light sensor end of the meter under a desktop or flat surface so as to block any light can accomplish this.
  • Page 11: Other Functions

    * For the CMM measurement, the area size is " meter square ", the lower display will show " m-2 ". For the CMM, the area setting size is from 0.001 to 30.000 meter square. * For the CFM measurement, the area size is " feet square ", the lower display will show "...
  • Page 12: Battery Replacement

    2) With the REC symbol on the display : (a) Press the " REC Button " ( 3-3, Fig. 1 ) once and the " Max " symbol along with the maximum value will appear on the display. (b) Press the " REC Button " again, the " Min " symbol along with the minimum value will appear on the display.
  • Page 13: Other Accessories

    * Measuring Range : -50 to 400 ℃ * surface Temp. ( -50 to 752 ℉ probe. * Size : Temp. sensing head - 15 mm Dia. Carrying case Probe length - 12 mm. CA-52A * High quality carrying case with sash. 0701-LM-8010...