TEST SETUP & TESTING 806-870MHz
FAST RE-SELECT THRESHOLD: 10dB
FAST RE-SELECT HYSTERESIS: 10dB
23. Press the "Return" soft key.
24. Press the "Trunk Type" soft key and the "message Trunked" soft key
25. Press "More" Softkey.
Note: The displayed values are factory defaults and should not be changed.
It is not required to configure "Call Types" "Call Times" and "Messages".
26. Press "More" Softkey.

How to Configure the IFR 2968 Manual Test Screen

1. To enter "Manual test" screen, press "Manual" soft key.
2. Press "Control Channel" soft key. Thereafter, "2072" and press "Control
3. Press "Traffic Channel" soft key. Enter "2072" and press "Traffic Channel" soft
4. Press "RF Gen Level" soft key. Thereafter, enter "-75" and press "dBm" data
5. Press "Mobile Power" soft key, enter 30 dBm/1W, using soft key.
6. Press "Burst Type" soft key and "Normal" soft key.
Note: The System Setup Configuration Data is saved even after the power is
MTP850 TETRA Handportable Terminal / Basic Service Manual
(Transmission).
Channel" soft key (IFR 2072 = Rx 851.81250MHz).
key. The marker goes to Timeslot. Enter "3" and press "Traffic Channel" soft
key. (Note that the Traffic Channel number changes automatically after
entering the Control Channel number).
keys followed by "RF Gen Level" soft key.
This completes the test equipment configuration setup.
turned off. However, the Manual Test Setup is not saved.