Repair
REPAIRS FOR MOTOROLA PRODUCTS WITH INTRINSICALLY SAFE APPROVAL ARE THE
RESPONSIBILITY OF THE USER.
• Repairs to a Motorola FM approved radio product should only be done at a location that
has been FM audited under the FM 3605 repairs and service standard.
• Contact Motorola for assistance regarding repairs and service of Motorola intrinsically
safe equipment.
A repair constitutes something done internally to the unit that would bring it back to its original
condition.
Items not considered as repairs are those in which an action is performed on a unit which does not
require the outer casing of the unit to be opened in a manner which exposes the internal electrical
circuits of the unit.
Do Not Substitute Options or Accessories
The Motorola communications equipment certified as intrinsically safe by the approving agency,
(FM, UL, CSA, CENELEC or ATEX) is tested as a complete system which consists of the listed
agency Approved portable, Approved battery, and Approved accessories or options, or both. This
Approved portable and battery combination must be strictly observed. There must be no substitution
of items, even if the substitute has been previously Approved with a different Motorola
communications equipment unit. Approved configurations are listed by the Approving Agency (FM,
UL, CSA, CENELEC or ATEX).
The Intrinsically Safe Approval Label affixed to radio refers to the intrinsically safe classification of
that radio product, and the approved batteries that can be used with that system.
The manual PN referenced on the Intrinsically Safe Approval Label identifies the approved
Accessories and or options that can be used with that portable radio unit.
Using a non Motorola intrinsically safe battery and or accessory with the Motorola approved radio
unit will void the intrinsically safe approval of that radio unit.
European Union Directives Conformance Statement
This product is in conformance with the TETRA (TErrestrial Trunked RAdio) standard.
This product is in conformance with the requirements of the applicable EU Council Directives.
Declarations of Conformance with the requirements are located at:
Motorola a/s
Sydvestvej 15
DK-2600 Glostrup
Denmark