Configure CC to monitor the connectivity among all MEPs in MD_A and MD_B. Configure the
device to use LB to locate link faults.
After the status information of the entire network is obtained, use LT to identify path and locate
faults.
Figure 8 Network diagram for CFD configuration
Configuration procedure
Configure a VLAN and assign ports to it.
1.
On each device shown in
GigabitEthernet 1/0/4 to VLAN 100.
Enable CFD.
2.
# Enable CFD on Device A.
<DeviceA> system-view
[DeviceA] cfd enable
Enable CFD on Device B through Device E using the same method.
Configure service instances.
3.
# Create MD_A (level 5) on Device A, create MA_A, which serves VLAN 100, in MD_A, and create
service instance 1 for MD_A and MA_A.
[DeviceA] cfd md MD_A level 5
[DeviceA] cfd ma MA_A md MD_A vlan 100
[DeviceA] cfd service-instance 1 md MD_A ma MA_A
Configure Device E as you configure Device A.
# Create MD_A (level 5) on Device B, create MA_A, which serves VLAN 100, in MD_A, and then
create service instance 1 for MD_A and MA_A. Also, create MD_B (level 3), create MA_B, which serves
VLAN 100, in MD_B, and then create service instance 2 for MD_B and MA_B.
[DeviceB] cfd md MD_A level 5
[DeviceB] cfd ma MA_A md MD_A vlan 100
[DeviceB] cfd service-instance 1 md MD_A ma MA_A
[DeviceB] cfd md MD_B level 3
8, create VLAN 100, and assign ports GigabitEthernet 1/0/1 through
Figure
31