5 Pressing the Emergency Stop button during travel will stop the lift
immediately and activate the alarm. The Emergency Stop overrides the
landing station controls. Pull the Emergency Stop out to return the lift to
normal operation.
6 Pressing the Alarm button during travel will activate the alarm. If the door
is locked at a landing, you can press the Alarm button to unlock the
current landing door.

Operating from the Landing Station Controls

Figure 3 shows the different types of landing stations (hall calls).
Figure 3
Flush Mount
To operate the V1504 from the landing (call/send) station controls:
1 Insert the key into the key switch (if equipped) and turn it to the ON position
to activate the operating buttons.
2 Press the appropriate button to move the lift in the required direction. Note
that the V1504 will not move if one of the doors is open.
3 When the lift reaches the landing, the door will unlock automatically (for
units with mechanical GAL locks). For units with an electric strike, the door
will unlock automatically for a few seconds when the lift reaches the
landing. If you need to re-open the door after the delay, turn the key on and
press the call button again to unlock the door.
4 To prevent unauthorized use of the lift, take the key out when the unit is not
in operation.