(4) Replacing the solenoid with a new one

circuit from damage.
Detach the gun cover and gun slide.
(See P-69.8-3-5 (2) "How to Open the Gun Slide" and P-70.8-3-5 (3) "How to Open the
G u n
C o v e r . " )
Disconnect the connectors of the solenoid.
Remove the cap bolt (M3 x 10) on the gun cover(L) and detach the solenoid bracket.
Remove the cup screw (M) (M3 x 8) and detach the ground wire.
Loosen the nuts (16mm in nominal diameter) fixing the solenoid.
Pull out the solenoid.
Remove the two cup screws (M) (M4 x 6) and detach the slide guide.
Pull out the solenoid plunger. At that time, take care not to lose the spring.
Cup screw (M) (M3 x 6)
q
Attach the components in reverse order. At that time. match the D-type hole of the sole-
noid bracket to the D shape of the solenoid. Alsd pay attention to the order to attach the
E-type snap rings and spacers.
Plunger
Toothed
washer
Slide guide
Spacers
E-type snap rings
7 1
off the power switch to protect the electric
x6) (----- ____ -----------;
, Cap bolt (M3 x 10)
I
I
I
I
I
I
I
I
I
I
I
I
I
,
_ _ _ _ _ _ _ _
face downwards)