5. INSTALLATION
5-2-l
Dividing the signboard Assy and cabinet Assy
-To be conducted by a technician only -
This task need not be conducted if the ceiling above the carry-in passage and the opening of the
access door are high enough.
Remove the two torque bolts (M5 x 12) from the back of the signboard Assy and detach the
connector cover.
q
Unplug the connector of the signboard Assy.
q
Remove the three hexagon bolts (with flat and spring washers) (M6 x 30).
q
Slide the signboard Assy backwards to the rope hook. Lift and remove the signboard Assy.
Torque bolt (M5 x 12)
q
In re-coupling these components together, follow reverse order.