Set Parameters - Vega VEGADIF 65 Operating Instructions Manual

4...20 ma/hart differential pressure transmitter
Table of Contents

Advertisement

Introduction
Application
Unit of measurement
VEGADIF 65 • 4 ... 20 mA/HART
6 Adjustment with the indicating and adjustment module PLICSCOM

6.4 Set parameters

VEGADIF 65 has general adjustment parameters which are also used
for other measuring principles as well as instrument-specific adjust-
ment parameters. The general adjustment parameters are described
in the operating instructions manual "Indicating and adjustment
module".
The instrument-specific adjustment parameters are described in this
chapter.
Information:
If the adjustment limits of the adjustment parameters are exceeded,
the message "Outside parameter limits" appears. The editing
procedure can be aborted with [ESC] or the displayed limit value can
be accepted with [OK].
VEGADIF 65 can be used for differential pressure, level as well as flow
measurement. The selection is made in the menu item "Application".
Depending on the selected application, the adjustment is carried out
as zero/span or min./max. adjustment.
Proceed as follows to switch over to the application level or flow
measurement:
Push the [OK] button in the measured value display, the menu
1
overview is displayed.
Basic adjustment
Display
Diagnostics
Service
Info
Confirm the menu "Basic adjustment" with [OK].
2
Application
Differential pressure
Confirm the menu item "Application" with [OK].
3
Warning:
Note the warning: "Output can change".
Select with [->] "OK" and confirm with [OK].
4
Select the requested application in the selection list, for example
5
"Flow" and confirm with [OK].
In this menu item you select the adjustment unit as well as the unit for
the temperature indication in the display.