Three-level comparator mode...Set the LO limit value.
Seven-level comparator mode...Set the level 2 lower limit value.
(No reply for the function setting "5if1 0 ".)
Send the six-digit value excluding the polarity and decimal point.
Command
Reply
 Five-level comparator mode...Not used
Three-level comparator mode...Not used
Seven-level comparator mode...Set the level 1 lower limit value.
(No reply for the function setting "5if1 0 ".)
Send the six-digit value excluding the polarity and decimal point.
Command
Reply
Replies to the commands other than examples above when the function setting "
.
1
" is selected
 The scale is not in a state where a command could be executed. Then, the scale will reply "I".
Command
Reply
 Command does not exist for the
Command
Reply
 When the function setting "5if1 0 " is selected, undefined commands are ignored and no
reply is sent.
HV/HW-C/CP Series
L 2
,
+ 0 0 0 1 0 0 C
L 2
,
+ 0 0 0 1 0 0 C
L 3
,
+ 0 0 0 0 0 0 C
L 3
,
+ 0 0 0 0 0 0 C
Z C
L
R
F
The scale is not in a condition that zero operation is possible.
I C
L
R
F
HV/HW-C/CP series
B C
L
R
F
The scale received an undefined command.
? C
L
R
F
L
R
F
L
R
F
L
R
F
L
R
F
. Then, the scale will reply "?".