Camera Control Interface Setting - Sony CH140 Application Manual

Pan/tilt/zoom/focus
Table of Contents

Advertisement

Application Guide
ER520
ER521
CGI
camera.cgi AutoFlip
CGI Syntax:
http://ip_adr/command/camera.cgi?AutoFlip=value

4.2.5. Camera Control Interface Setting

EX101
EX101E
CGI
system.cgi
CGI Syntax:
http://ip_adr/command/system.cgi?CameraControlInterface=value
Sony Network Camera
ER550
ER580
ER585
ER585H
RH124
Parameter
Value
off
0, 500, or 750
EX104
EX154
Parameter
CameraControlInterface
Pan/Tilt/Zoom/Focus
RH164
RS44
RS46
RS84
Disables the auto fl ip function that automatically
switches the tilt movement of the camera
downward to upward when the camera tilts
downward to the point where it faces the ground.
Enables the auto fl ip function and also sets the
latency time from when the camera movement
tilts completely and stops itself until it restarts
tilting. Settable values are 0, 500 or 750 (msec).
Note:
0, 500 and 750 are not available for SNT-EX101/
EX101E/EX104/EX154.
Value
Sets the camera control interface to Coaxitron
coaxitron
interface.
Sets the camera control interface to Serial
serial
interface.