6000 Series Purge/Pressurization System

6000 Control unit with housing "WH"

Tools:
Appropriate sized drill bits or knockout holes
1 1/16" open end box wrench
Bolts: 1/4-20 (provided),
hole clearance = 0.27" (6.86 mm) diameter
EFC-6-SS (provided):
hole clearance = 0.61" (15.54 mm) diameter
1/4-20 pan head bolts
(3 included)
1/4-20 pan head
w/lock washer screws
(4 included)
Grounding lug
(included)
Mounting bracket
(included)
6000 control unit
1. Drill holes using template. Check the scale if
printing an electronic version.
2. Assemble tubing and fitting to control unit. Install
on the "Out" port of the correct side.
3. Bolt mounting plate to the enclosure. Type 4X
washers must be mounted inside the enclosure.
Tighten to 60 – 80 in-lb (16.38 – 18.08 Nm).
0.61" (15.54 mm) hole
Ø
Ø 0.27" ( 6.86 mm)
hole (3x)
3/8" stainless steel tube, 2.5" (65 mm) long (included)
3/8" ferrule fitting (included)
Seal washer (3 included)
Lock washer (3 included)
1/4-20 nuts (3 included)
EFC-6-SS nut (included)
EFC-6-SS (included)
4. Put 2 of the mounting screws in the back of the
control unit to align with the key holes in the
mounting plate.
5. Hang the control unit onto the plate. Slide the unit
towards the enclosure so that the EFC-6-SS fitting
is in the proper location.
6. Tighten the 2 bolts. Put the other two mounting
bolts in place and tighten.
7. Place the EFC-6-SS bolt in position and tighten.
I/O Manual
Locking nut
w/grounding screw
(included)
Seal gasket
(included)
Vent cap
(included)
EPV-6000
Vent cable
(included)
Enclosure
15