Pepperl+Fuchs 6000 SERIES Installation And Operation Manual page 56

Purge/pressurization system
Hide thumbs Also See for 6000 SERIES:
Table of Contents

Advertisement

6000 Series Purge/Pressurization System
20 to 30 ft
3
(0.57 to 0.85 m
)
3
> 30 ft
3
(0.85 m
)
3
Flow rate for leakage compensation
EPV-6000-xx-01, 02
0.35 SCFM @0.25" wc (10.0 l/min @ 6.3 mbar)
1.0 SCFM @0.75" wc (28.0 l/min @ 1.9 mbar)
EPV-6000-xx-03, 04
0.22 SCFM @0.25" wc (6.2 l/min @ 6.3 mbar)
0.58 SCFM @0.75" wc (16.4 l/min @ 1.9 mbar)
EPV-6000-xx-05, 06
0.15 SCFM @0.25" wc (4.2 l/min @ 6.3 mbar)
0.35 SCFM @0.75" wc (10.0 l/min @ 1.9 mbar)
Inlet fitting to manifold:
Outlet fitting from manifold:
Mechanical specifications
Storage temp:
6000 control unit (all versions)
EPV-6000 vents:
6000-TEMP hub:
6000-TSEN sensor:
6000-ISB-01:
6000-DPE-...:
Operation temp:
6000 control unit
6000-xx-S2-UN-xx-xx -20 °C to +50 °C (-4 °F to +122
-20 °C to +60 °C (-4 °F to +140 °F)
6000-xx-S2-UN-CK-xx -20 °C to +60 °C (-4 °F to +140 °F)
6000—UIC-01
-20 °C to +60 °C (-4 °F to +140 °F)
EPV-6000 vent
-20 °C to +60 °C (-4 °F to +140 °F)
6000-TEMP hub:
-20 °C to +60 °C (-4 °F to +140 °F)
6000-TSEN sensor: -20 °C to +100 °C (-4 °F to +212 °F)
6000-ISB-01:
-20 °C to +60 °C (-4 °F to +140 °F)
6000-DPE-...:
-20 °C to +60 °C (-4 °F to +140 °F)
6000 control unit
Protection class (all electronics):
Weight:
Power connections:
52
5, 12, 20 SCFM
(141, 340, 565 l/min)
5, 12, 20, 30 SCFM
(141, 340, 565, 850 l/min)
Depends on
enclosure seal
3/8" tubing (included)
3/8" bulkhead fitting
(included)
-30 °C to +80 °C (-22 °F
to +176 °F)
-30 °C to +80 °C (-22 °F to
+176 °F)
-20 °C to +70 °C (-4 °F to
+158 °F)
-20 °C to +100 °C (-4°F
to +212 °F)
-20 °C to +60 °C (-4 °F to
+140 °F)
-20 °C to +60 °C (-4 °F to
+140 °F)
°F) For Dust application
For Gas application
Type 4X, IP66
control unit: 25 lbs (11.4 kg)
3/4" NPT male pipe
(explosion-proof seals required)
I.S. input connections:
Material:
Enclosure:
316L (UNS S31603) stainless steel
Manifold valve:
Fittings:
316L (UNS S31603) stainless steel
I.S. cable glands:
Terminal blocks EPCU:
Power terminal block:
torque 5-7 in-lbs (0.6 to 0.8 Nm)
I.S. terminal block:
EPV-6000 relief vent
Flow rate measurement
Flow rate is measured in increments, 5, 12, 20, 30 SCFM
(141 l/min, 340 l/min, 565 l/min, 850 l/min, & Dynamic)
Protection class:
EPV-6000-___-05,06:
Weight:
Power connections:
(mating connector with cable comes with
vent for connection to the control unit)
LED indication
Max cable length:
Maximum run length 18.3 m (60 ft)
Mounting:
Mounting can be any orientation to the
enclosure. Not dependent on gravity.
Mounting hole:
Material:
EPV-6000-AA-....:
Cap:
Marine grade anodized 5053 aluminum
Body:
Marine grade anodized 6061 aluminum
EPV-6000-SS-....:
Cap:
316L (UNS S31603) stainless steel
Body:
Marine grade anodized 6061 aluminum
Spark arrestor assembly:
Protected with 304 (UNS S30400) stainless steel
spark arrestor screen. Cap is movable so that
opening can be positioned downwards.
User interface controller
Max cable length: 24 AWG (0.20 mm
I/O Manual
Terminal connection inside
6000 series unit
Anodized 6082 aluminum
M16 x 1.5 (5.5 - 10 mm) (4)
Conductors 26-14 AWG
(0.13 - 2.08 mm
Conductors 28 - 16 AWG
(0.08 - 1.31 mm
torque 4 in-lbs (0.5 Nm)
& Dynamic,
Mounting fitting Type 4X, IP66
Ingress protection from vent to
pressurized enclosure, Type 4X
3 lb (1.4 kg)
M12 (V1) pin connector,
intrinsically safe
GREEN – Power to EPV vent
AMBER – 2nd vent address for
two vent / one EPCU system
22 AWG (0.33 mm
) wire = 5 m
2
(16.5 ft)
1 ½" NPT knockout
(
2", 50.8 mm) hole,
Ø
mounting with sealed nut
) wire = 12.2 m (40 ft)
2
),
2
),
2