Diagnostic Codes - Goodman AVPTC42D14 series Installation & Operating Instructions Manual

Avptc**14 series
Table of Contents

Advertisement

26 Diagnostic Codes

7 SEGMENT LED
(characters will
alternate)
(no display)
On
Ed
Eb
E5
EF
d0
d1
d4
b0
b1
b2
b3
b4
b5
b6
b7
b9
C1
C2
P1
P2
h1
h2
FC
FH
F
H1
H2
dF
GREEN CFM LED - EACH FLASH REPRESENTS 100CFM (USE FOR AIRFLOW
INTERNAL CONTROL FAULT / NO POWER
HEATER KIT DIP SWITCHES NOT SET PROPERLY
NO HTR KIT INSTALLED - SYSTEM CALLING FOR AUXILIARY HEAT
BLOWER MOTOR COMMUNICATION ERROR
BLOWER MOTOR OPERATING IN POWER, TEMP., OR SPEED LIMIT
BLOWER MOTOR CURRENT TRIP OR LOST ROTOR
BLOWER MOTOR ROTOR LOCKED
OVER/UNDER VOLTAGE TRIP OR OVER TEMPERATURE TRIP
INCOMPLETE PARAMETER SENT TO MOTOR
LOW STAGE COOL - LEGACY MODE ONLY
HIGH STAGE COOL - LEGACY MODE ONLY
LOW STAGE HEAT PUMP HEAT - LEGACY MODE ONLY
HIGH STAGE HEAT PUMP HEAT - LEGACY MODE ONLY
EMERGENCY HEAT LOW - COMMUNICATING MODE ONLY
EMERGENCY HEAT HIGH - COMMUNICATING MODE ONLY
FAN COOL - COMMUNICATING MODE ONLY
FAN HEAT - COMMUNICATING MODE ONLY
DEFROST - COMMUNICATING MODE ONLY
(note: defrost is displayed as H1 in a legacy setup)
APPROXIMATION ONLY) - EXAMPLE: 8 FLASHES = 800CFM
DESCRIPTION OF CONDITION
STANDBY, WAITING FOR INPUTS
FUSE OPEN
AUXILIARY SWITCH OPEN
DATA NOT ON NETWORK
INVALID DATA ON NETWORK
INVALID MEMORY CARD DATA
BLOWER MOTOR NOT RUNNING
BLOWER MOTOR HP MISMATCH
LOW INDOOR AIRFLOW
FAN ONLY
ELECTRIC HEAT LOW
ELECTRIC HEAT HIGH
31
0140A00079-A

Hide quick links:

Advertisement

Table of Contents
loading