Air Handler Advanced Features Menu - Goodman AVPTC42D14 series Installation & Operating Instructions Manual

Avptc**14 series
Table of Contents

Advertisement

24 Air Handler Advanced Features Menu

Submenu Item
Electric Heat Size (HTR KW)
Motor HP (1/2, 3/4, or 1 MTR HP)
Heat ON Delay (HT ON)
Heat OFF Delay (HT OFF)
Submenu Item
Fault 1 (FAULT #1)
Fault 2 (FAULT #2)
Fault 3 (FAULT #3)
Fault 4 (FAULT #4)
Fault 5 (FAULT #5)
Fault 6 (FAULT #6)
Clear Fault History (CLEAR)
NOTE: Consecutively repeated faults are shown a maximum of 3 times
Submenu Item
Model Number (MOD NUM)
Serial Number (SER NUM)
Software (SOFTWARE)
Submenu Item
Heat Airflow Trim (HT TRM)
Submenu Item
Mode (MODE)
CFM (CFM)
CONFIGURATION
Indication (for Display Only; not User Modifiable)
Displays the size in kW of the selected electric heaters.
Displays the air handler indoor blower motor horsepower.
Displays the electric heat indoor blower ON delay.
Displays the electric heat indoor blower OFF delay.
DIAGNOSTICS
Indication/User Modifiable Options
Most recent modular fault
Next most recent modular fault
Next most recent modular fault
Next most recent modular fault
Next most recent modular fault
Least recent modular fault
NO or YES
IDENTIFICATION
Indication (for Display Only; not User Modifiable)
Displays the modular blower model number
Displays the modular blower serial number (Optional)
Displays the application software revision
SET-UP
User Modifiable Options
-10% to +10% in 2% increments, default is 0%
STATUS
Indication (for Display Only; not User Modifiable)
Displays the current air handler operating mode
Displays the airflow for the current operating mode
23
Comments
For display only
For display only
For display only
For display only
For display only
For display only
Selecting "YES" clears the fault history
Comments
Trims the heating airflow
by the selected amount.

Hide quick links: