Smoke Chamber Cleaning - LASIAN AUDAX 6 KW User And Installation Manual

Up to 12kw
Table of Contents

Advertisement

The stove has a flame retainer in the upper part of the combustion chamber, to access it and clean it, manually
disengage the top of the stove (see Fig. 9.5).
The parts showed by the arrows in Figure 1 are interior parts of the combustion chamber which
leaving factory painted to avoid rusting during storage. Once the stove is working this painting
begins to spoil due to high temperatures. To remove evenly rub with a steel wool.

9.6 SMOKE CHAMBER CLEANING

Usually once a year (preferably at the beginning of the season), the extraordinary cleaning of the smoke chamber
must be performed to allow a correct operation of the stove. The frequency of this operation depends on the type
of fuel used and the frequency of use. To perform this cleaning it is advisable to contact a Technical Assistance
Center.
9.7 UNLOAD INSTALLATION CLEANING (CHIMNEY)
It is recommended to proceed with this maintenance in the extraordinary cleaning phase. Removing the "T" plug
connector and cleaning all the duct. It is necessary that at least the first time this is carried out by qualified staff.
It is also recommended to clean the "T" plug at least monthly.
9.8 GLASS DOOR CLEANING
Periodically clean the glass door of the stove with a degreaser product (non-corrosive or abrasive). If the glass is
still hot, before cleaning, leave the stove door open the necessary time to cool it. Do not use materials that may
damage or scratch the glass.
Do not spray the product for the glass cleaning on painted parts of the stove or joints of the fire
door (fiberglass cord).
COD. 83119L.01EN
Fig. 9.5
44
09//2016