Installation - LASIAN AUDAX 6 KW User And Installation Manual

Up to 12kw
Table of Contents

Advertisement

If during operation of the stove fuel burns so fast that there is almost never flame in the burner (even it can
appears the "Er03" alarm), it is because the air supplied by the extractor is excessive for the amount of
pellets that are loading.
In this case, we can do two things:
-
-

5. INSTALLATION

The installation of LASIAN Air Stoves must be only carried out by qualified staff,
following the manufacturer's instructions and in accordance with all standards
and regulations that are applicable. Otherwise, the manufacturer is not liable for
any accident.
5.1 CHOICE OF LOCATION
It is forbidden to install the stove outside (exposed to the atmospheric agents) or in wet areas,
as well as in bedrooms, locations with bath or shower and in places where there is another
heating unit if they do not have the suitable dimensions and devoid of an adequate airflow.
When we choose the location of the stove, we will try that the route until the flue gas duct connection were as short
as possible, and flue gas can be discharged easily (check paragraph "5.4- DUCT OR CHIMMEY").
Since in both, the stove and in the flue gas ducts it can be reached high temperatures, you have to follow certain
rules and safety recommendations to prevent possible fires and dangerous situations, so to make the installation
check paragraph "5.3- DOMESTIC FIRE PREVENTION".
To ensure the air supply for the combustion in the stove, and keep a suitable ambient conditions, it has to keep in
mind everything with reference to ventilation which is explained in paragraph "5.5- AIR INTAKE AND
VENTILATION."
We must also have a suitable power point near the stove (check paragraph "5.6- ELECTRIC CONNECTION"), so
that the installation has finished, the power cord that comes with the stove can be connected and disconnected
easily.
To make easier the loading of the pellet and the access to the control panel, as well as the maintenance or any
intervention in the stove, it will be necessary to leave a minimum distances above and around it. A reference to
follow might be the ones described in paragraph "5.3.1 MINIMUM SAFETY DISTANCES", although at least on the
right side of stove, it would be convenient to leave a minimum distance of 400 mm. in order to access to the rear
side of the stove.
Installation and use of the product should be in accordance with the manufacturer's
instructions, obeying European, national and local regulations where the product is
installed.
5.2 UNPACKING
Unpack the product carefully so it does not get damaged or scratched. Remove from the tank of the stove the
accessory bag (it contains the legs of the stove, the power cord, the remote control, for the models which take it
and the instructions manual) and from the combustion chamber possible pieces of polystyrene or cardboard used
to block the removable parts, etc.
Also keep out of reach of children parts of the packaging (plastic bags, polystyrene, etc.) that could be potentially
dangerous and dispose according to the existing laws.
COD. 83119L.01EN
Decreasing the amount of supplied air with negative steps of the fan (check 6.1.7).
Increasing the fuel load with positive steps in pellet calibration (check 6.1.6).
Before changing the fan and pellet calibration, it is necessary to make sure everything is
correct: installation, maintenance and cleaning, etc. For this we can check the chapter 8-
ALARMS, MENSSAGES AND PROBLEMS".
It is preferable to change first the fan calibration, so the pellet load also modify the output of the
stove.
14
09//2016

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Audax 8 kwAudax 10 kwAudax 12 kw

Table of Contents