6.1.6- PELLT LOAD CALIBRATION

The pellet combustion and the general performance of the stove depends on the type of pellet it is used and on the
configuration of the flue duct. If anyone of them is really different from the standards with which the stove was
adjusted in factory, it may be necessary to readjust the load of pellet to adapt it to the current conditions.
If the user observes the stove performance, the user will know if it is advisable decrease or increase the pellet load
as explained in "4.3- USER SETTINGS DEPENDING ON THE PELLET THAT HAS BEEN USED".
Pellet load calibration is carried out by steps, 7 positives and 7 negatives which increase or decrease respectively
(proportionally) the percentage of load with regard to factory settings (the percentage is with a step adjusted to
"0").
To access the pellet load calibration a long keystroke of the push-button
"Pell" in the display that is below, also we will see at the same time in the display on top the current value of the
step. To modify it we have to push a long keystroke again of the push-button
After this, with short keystrokes of the push-buttons
be increased or decreased.
After 5 seconds, the new value is saved and the display returns to the main screen.
The values with negative sign are the negative steps (decrease of the load), whereas the ones that
have no sign are positive steps (increase of the load).
The stove has a control system which adjusts automatically the loading of pellet, so this user
adjustment will not appear, or if it appears must remain at "0" in order not to interfere with the
electronic board adjustment.
6.1.7- COMBUSTION FAN CALIBRATION
The pellet combustion and the general performance of the stove depends on the type of pellet it is used and on the
configuration of the flue duct. If anyone of them is really different from the standards with which the stove was
adjusted in factory, it may be necessary to readjust the load of pellet to adapt it to the current conditions.
If the user observes the stove performance, the user will know if it is advisable decrease or increase the pellet load
as explained in "4.3- USER SETTINGS DEPENDING ON THE PELLET THAT HAS BEEN USED".
Fan calibration is carried out by steps, 7 positives and 7 negatives which increase or decrease respectively
(proportionally) the speed of the fan with regard to factory settings (they come with a step adjusted to "0").
To access the speed of fan calibration a long keystroke of the push-button
"Vent" in the display that is below, also we will see at the same time in the display on top the current value of the
step. To modify it we have to push a long keystroke again of the push-button
After this, with short keystrokes of the push-buttons
be increased or decreased.
After 5 seconds, the new value is saved and the display returns to the main screen.
The values with negative sign are the negative steps (decrease of the speed), whereas the ones that
have no sign are positive steps (increase of the speed).
The stove has a control system which adjusts automatically the combustion fan speed, so this
user adjustment will not appear, or if it appears must remain at "0" in order not to interfere with
the electronic board adjustment.
COD. 83119L.01EN
(DEACTIVATED FROM FACTORY)
or
(P2 and P4) the step value will flicker and then, it can
(DEACTIVATED FROM FACTORY)
or
(P2 and P4) the step value will flicker and then, it can
27
(P2) has to be made until we see
until we hear an acoustic signal.
(P4) has to be made until we see
until we hear an acoustic signal.