8.3 ALARMS

The control panel has some systems that control: the ignition, pellet, working power, room temperature, fume
temperature, the proper working of the fan, the proper outlet of pellet combustion gases, etc.
The alarms are used by the control panel to inform us that there is something that blocks the normal working of the
stove:
ALARM
DESCRIPTION
CODE
Activation of the
security thermostat
Er01
Activation of the safety
air pressure switch
Er02
Shut down for a low
Er03
fumes temperature
Shut down for a high
Er05
fumes temperature
The electronic board
does not receive any
signal from the speed
Er07
controller of the
extractor (combustion
fan)
COD. 83119L.01EN
POSSIBLE CAUSE
 Security
Klixon
and/or
damaged
The temperature in the hopper has
increased a lot
The chimney is very dirty or blocked.
Chimney has a lot of pressure loss:
excessive length, excessive horizontal
section, insufficient diameter, incorrect
finish or with net, too much bends, etc.
Setback of the fumes caused by air
action.
The last case may be a problem of the air
pressure switch or of its connection with
the control panel.
There is little pellet in the hopper
A "cave" in the hopper has been
produced and the pellet do not arrive to
the load auger
The load auger has been blocked
or/and the load motor does not spin
There is a high temperature in the room
Room fan does not work or it works very
slowly.
The fumes probe is missing or has been
damaged. In this case, it would appear
"Hi"
in
the
fumes
information
"tF",
and
thermostat is working to the maximum.
It may appear sometimes because of
fluctuations in the electric network.
The fumes fan and/or any of its
connections are damaged.
38
cable
are
Call the Technical Assistance Service.
Check and clean the chimney.
Check and correct the installation.
Check the position of the flue duct and
make sure the cowl is suitable.
If you have checked and corrected
every previous step, and the alarm
keeps appearing, call the Technical
Assistance Service.
Reset the error.
Make sure that the pellet arrives to the
auger (undo the "cave"), put pellet in
the hopper if necessary, and fill up the
auger (see chapter 6.1.3).
If after several attempts of filling up
the auger, it does not fall pellet into the
burner, call the Technical Assistance
Service.
Check the selected room temperature
and that the room thermostat is placed
in a proper place in order to detect the
temperature of the room.
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
temperature
the
room
Reset the error and turn it on again.
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
SOLUTION