8.1 PROBLEMS

Here you have some advices just to make sure that everything is correct before turning on the stove, and power
up the stove with the best guarantees:
Check that the installation has been carried out according to the prevailing rules and following the advices
of the manufacturer (see the chapter "5. INSTALATION").
Use only the proper pellet (see chapter "4. FUEL"), as short and as uniform as possible, keeping a
minimum level of load at half in the hopper.
If the pellet has been in the hopper for a long time, it can catch air humidity so it is advisable to empty the
hopper and put the pellet again. If, for some reasons, you use the pellet with humidity, it would be an
excess of smoke during the ignition state.
Perform the maintenance as the manufacturer says in chapter "9. CLEANING AND MAINTENANCE", do
not forget to clean the brazier every 8 or 12 hours maximum (depending on the pellet that has been used)
and then, place it correctly.
A malfunctioning of the stove comes with a message or alarm, even though it not always happens. The list of
possible cases provided below can be checked before warning the Technical Assistance Service (TAS):
When we turn on the stove, the differential of the house is set off. In this case, the first step would be trying
to connect the stove to another plug and, if the problem persists it may be a problem of humidity in any of
the components so we should make sure that the stove receives neither air humidity nor humidity through
the chimney. After that, wait several hours before trying it again.
The screen does not turn on. Check the voltage in the plug, see if the rear switch is on, maybe the rear
fuse is burnt out...
In days of strong wind or adverse weather conditions, it is possible that the stove combustion is not
good due to the influence in the draught of the chimney. The manufacturer does not assume any
responsibility for the malfunctioning of the stove under adverse weather conditions.
8.2 MESSAGES
MESSAGE
sensor. The message appears during the state of "Check
Sond
Up", and indicates that the temperature or airflow detected
by one or more probes are not between the minimum and
Indicates that the room temperature is more than 50 ºC.
Hi
Ordinary maintenance: message that appears after 300
CLr
Extraordinary maintenance: message that appears after
1500 hours of the stove working in order to an exceptional
Serv
maintenance is carried out by the Technical Assistance
PCLr
COD. 83119L.01EN
MESSAGE MEANING
Display of the state of the room thermostats or airflow
maximum allowed values.
The room thermostat may be in a short.
hours of the stove working in order to a routine
maintenance is carried out by the user.
Service.
Periodic self-cleaning of the burner that the electronic
board carries out while the stove is working.
Check the state and connection of the
Inform the TAS if it is not solved.
Check the state and connection of the
Inform the TAS if it is not solved.
See chapter "9-CLEANING AND
To deactivate the message and reset the
It is necessary to carry out a general
cleaning of the device and of the smoke
outlet installation. Contact with the
Technical Assistance Service of the area
or authorized professional. See chapter
"9-CLEANING AND MAINTENANCE"
No action is required. After the time of
the cleanliness has elapsed, the
37
ACTION TO PERFORM
probes.
room thermostat.
MAINTENANCE".
counter, see chapter 6.2.5
message will disappear.