ALARM
DESCRIPTION
CODE
The speed of the
extractor cannot be
Er08
adjusted properly
Update DATE and
Er11
TIME
Er12
Error in the ignition
Er15
Electric supply cut
Flow meter sensor
Er39
damaged
The minimum
has not been reached
Er41
during the "Check Up"
COD. 83119L.01EN
POSSIBLE CAUSE
It may appear sometimes because of
fluctuations in the electric main.
The voltage main is not good or is taken
from a non-sinusoidal AC generator
Fumes fan and/or any of its connections
are damaged
It can appear the first time the stove is
connected to the network or after several
days of being unplugged.
IF THE BURNER IS ALMOST EMPTY
There is little pellet in the hopper
. A "cave" in the hopper has been
formed, and the pellet does not get to
load auger.
 The load auger is blocked and/or the
load motor does not turn.
IF THE BURNER IS FULL OF PELLET
(NOT BURNED)
The burner is dirty.
Wet pellet or bad quality pellet
 Ignition
resistance
connection cable are damaged.
There has been an electric supply cut for
a long period while the stove was
working, or while the ignition.
It may appear when the stove is turning
off if during the working the flow sensor
breaks down.
We may have a problem in the flue
duct.
 The air inlet is blocked totally or
partially, or it has been canalized and it
has lot of load loss
 Dirty burner
airflow
 The stove takes air of an inlet
unplanned: the door is open or not
closed properly; the hopper and/or load
auger has no pellet, etc.
 The interior fumes passages of the
stove are very dirty
 The extractor has lost power
Problems with the flow sensor or its
connection
(appears
Reset the error and turn it on again.
Make sure it is connected to a suitable
supply.
 In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
Update time and day of the week. (See
chapter 6.2.3).
Reset the error
Make sure that the pellet arrives to the
auger, put pellet in the hopper if
necessary, and fill up the auger (see
chapter 6.1.3).
If after several attempts of filling up
the auger, it does not fall pellet into the
burner, call the Technical Assistance
Service.
Empty and clean the burner, reset the
alarm and try another start-up.
Check the conditions and quality of
pellet
 If it does not start up after 2 or 3
and/or
the
attempts,
Assistance Service.
 Reset the error and start up again.
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
If the problem keeps on appearing,
when starting up the stove it will appear
the error "Er41".
Check all the possibilities that appears
in the error "Er02".
Check the stove and the installation
Check the stove cleanliness and flue
duct (see chapter 9)
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
the
message
39
SOLUTION
call
the
Technical
09//2016

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Audax 8 kwAudax 10 kwAudax 12 kw

Table of Contents