CONTROL PANEL
FOR 230 V GEARMOTORS
FA 00385 -E N
INSTALLATION MANUAL
ZM3E - ZM3EC - ZM3EP
EN
English
www.metalines.com
sales@metalines.com

Advertisement

Table of Contents
loading

Summary of Contents for CAME ZM3E

  • Page 1 CONTROL PANEL FOR 230 V GEARMOTORS FA 00385 -E N INSTALLATION MANUAL ZM3E - ZM3EC - ZM3EP English www.metalines.com sales@metalines.com...
  • Page 2: Reference Regulations

    This product complies with the current regulations mentioned in the declaration of conformity. DESCRIPTION ZM3E - ZM3EP Multifunction control panel for two-leaved swing doors, with graphic programming display and signaling, plus self-diagnosing safety devices. ZM3EC Multifunction control panel for two-leaved swing doors, complete with safety lock and buttons, with graphic programming display and signaling, plus self-diagnosing safety devices.
  • Page 3: Preliminary Checks

    29. CLOSING button ZM3EC 30. OPENING button 31. Safety lock CAME GENERAL INSTRUCTIONS FOR INSTALLING Only skilled, qualified staff must install this product. Before working on the control panel, cut off the main current supply and, if present, remove any batteries.
  • Page 4: Installation

    Tools and materials Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable regulations. The figure shows some of the equipment installers will need. Cable types and minimum thicknesses Cable length Cable length Connection...
  • Page 5: Electrical Connections

    ELECTRICAL CONNECTIONS Power supply to accessories Possible output of the second radio-receiver Terminal board for 24 V AC / DC accessories - Electrolock connection at 12 V - channel (NO contact). Maximum power: 20 W Maximum power: 15 W Contact rated for: 1 A-24 V DC.
  • Page 6 Command and control devices Before fitting any snap-in cards (such as the AF or R700), YOU MUST CUT OFF THE POWER MAINS, and disconnect the power mains.  Fit the AF card to control the operator via transmitter. Keypad selector Blue White Transponder or...
  • Page 7: Safety Devices

    Signaling devices Gate-open warning output (contact rated Cycle or courtesy light (contact rating: 230 V - 60 W max). for: 24 V AC - 3 W max). Auxiliary connection of an outdoor light which can be positioned To warn that the gate is open. where you like, to increase lighting in the driveway/parking area.
  • Page 8 Whereas with the sleep mode function, energy consumption is reduced when the photocells are on stand-by. Activate the Sleep Mode function from the [FUNCTIONS] menu. DIR / DELTA DELTA S Connection with Came Remote Protocol (CRP) A B GND 1 2 3 4 UTP CAT 5 Fit the RSE card.
  • Page 9: Cycle Time

    PROGRAMMING Description of programming commands the <-----> signs on the display are for: - showing the currently selected item The ESC button is for: The ENTER key is for: - exiting menus; - entering menus; - cancelling changes. - confirming or memorizing set values. The <...
  • Page 10 Partial Opening [Maint Action] Maintained Action [Auto Close] AutoClose [Config] Configuration [CRP] Came Remote Protocol [Assoc Function] Associated Feature [M1 Open Accel] M1 Opening approach as a percentage [M1 Close Accel] M1 Closing approach as a percentage [M1 Opn Slw Dwn]...
  • Page 11 [ENCODER] Default [Sensitivity] [Enabled] / [Disabled] [Enabled] ◦+] [Travel sens] ◦+] [Slw Dwn sens] [Enc Slow Down] [ON] / [OFF] [ON] [1%] ⇨ [60%] [M1 Opn Slw Dwn] [10%] [1%] ⇨ [60%] [M1 Cls Slw Dwn] [10%] [M2 Opn Slw Dwn] [1%] ⇨...
  • Page 12: Functions Menu

    Functions menu [FUNCTIONS] [Auto Close] [Disabled] / [Enabled] The fi rst automatic-closing wait starts when the opening endstop point is reached and can be set to between 0 and 300 s. The automatic closing does not turn on if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power outage. [Maint Action] [Disabled] / [Enabled] / [Closing] The gate leaves close by keeping a button pressed.
  • Page 13 ⇨ [CRP address] [32] With systems fitted with several operators and the CRP (Came Remote Protocol) system connection, set an address between 1 and 32 for each control panel. [CRP baudrate] [1200] / [2400] / [4800] / [9600] / [19200] / [38400] / [57600] / [115200] Setting the communication speed used in the CRP (Came Remote Protocol) connection system.
  • Page 14: Time Settings Menu

    [1%] ⇨ [M2 Opn Slw Dwn] [60%] Adjusting M2's slow-down starting point before the opening endstop. The slow-down starting point is calculated as a percentage (from 1% to 60% of the complete gate-leaf run).  This function only appears if the [Enc. Slwdwn.] function in the [ENCODER] menu. [1%] ⇨...
  • Page 15 Users Menu [USERS] [Add User] Entering up to 250 users and associating to each one a function of choice among those included. Enter by using a transmitter or other control device (see the ENTERING A NEW USER paragraph). [Change Name] changing the user number or name [Change Code] To modify the command code that is associated to a user...
  • Page 16 Entering a new user 1. From the 2. Select [Confirm? [USERS], select < Add User > Add User (Yes)] and press [Add User] <Confirm? (Yes)> ENTER to confirm. function. Press ENTER to confirm. 3. Select the function Assoc Function 4..a code to enter will to associate to users.
  • Page 17: Change Code

    Modify code 1. From the 2. Select the user name < Change Code > Change Code [USERS], select of which you want to [Change Code]. Change Code edit the code and press Press ENTER to ENTER to confirm. < 002: --U002-- > confirm 3.
  • Page 18 Travel calibration Before calibrating the gate run, check that the maneuvering area is free from any obstruction and that there are both opening and closing mechanical stops. The mechanical end-stops are obligatory. Important! During the calibration, all safety devices will be disabled except for the PARTIAL STOP one. 1.
  • Page 19: Dismantling And Disposal

    DO NOT DISPOSE OF IN NATURE! DECLARATION OF CONFORMITY Declaration - Came S.p.A. declares that this device conforms to the essential, pertinent requirements provided by directives 2004/108/EC and 2006/42/CE. An original copy of the declaration of conformity is available on request.