LOVATO ELECTRIC RGK400SA Instruction Manual

LOVATO ELECTRIC RGK400SA Instruction Manual

Stand-alone generating set controllers

Advertisement

CAUTION!
● Read this manual before use and installation.
● This equipment must be installed by qualified personnel according to applicable standards in order to prevent injury or damage to property.
● Before any maintenance operation on the device, disconnect power from all measuring and power supply inputs.
The manufacturer cannot be held responsible for electrical safety in case of improper use of the equipment.
● The products illustrated herein are subject to alteration and changes without prior notice. Descriptions and specifications are therefore not contractually binding.
● A circuit breaker must be included in the electrical installation of the building. This must be installed near the equipment and within easy of the operator. It must be marked
as the disconnecting device of the equipment: IEC/ EN 61010-1 § 6.12.2.1.
● Clean the equipment with a soft cloth; do not use abrasive products, liquid detergents or solvents.
Doc: I470GB10_16.docx
RGK400SA RGK420SA
STAND-ALONE GENERATING SET CONTROLLERS
INSTRUCTION MANUAL
Contents
Page
2
2
2
3
3
3
3
4
4
4
4
4
4
4
5
5
6
6
11
11
12
13
13
14
15
16
17
18
19
18/10/2016
p. 1 / 19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RGK400SA and is the answer not in the manual?

Questions and answers

Summary of Contents for LOVATO ELECTRIC RGK400SA

  • Page 1: Table Of Contents

    Page Introduction Description Functions of front panel buttons and controls Display indications Navigating between the display pages Switching on and starting up (RGK400SA) Switching on and starting up (RGK420SA) Expandability Inputs and outputs User alarms (UAx) IR programming port Parameter setting from PC...
  • Page 2: Introduction

    Introduction The RGK400SA and RGK420SA controllers implement state-of-the-art functions for use with manual control (stand-alone) generating sets. The RGK400SA incorporates front panel buttons for switching the controller on and off and starting and stopping the generator. On the RGK420SA, this function is performed by a key switch on the front panel.
  • Page 3: Display Indications

     To set up these functions, see the P01 – Utility menu. Switching on and starting up (RGK400SA)  To switch on the controller when battery power is present at the terminals, press and hold the STOP button for 1 seconds. The device switches on and performs a self-test.
  • Page 4: Expandability

     Thanks to its expansion bus, the RGK4...SA can be expanded with additional modules of the EXP... series.  The RGK400SA and RGK420SA support the EXP1040 expansion module, which provides additional 2 inputs and outputs.  Program at least one of the resources which the module will make available (for instance, assign the analog input AIN2 to fuel level).
  • Page 5: Parameter Setting From Smartphone Or Tablet Via Wi-Fi

    Parameter setting from smartphone or tablet via Wi-Fi It is possible to establish a wireless connection to the RGK4..SA using the LOVATO Electric SAM1 app, available for Android or iOS tablets and smartphones, and the CX02  accessory.  The app can be used to view alarms, send commands, read measurements, set parameters, download events and send collected data via e-mail.
  • Page 6: Parameter Settings (Setup) From Front Panel

    Default right indicator measurement %Fuel Oil Pr Temp V batt P01.08 Shutdown delay (RGK400SA only) OFF/1-1440 P01.01 – Display text language selection. P01.02 – High display backlight adjustment. P01.03 – Low display backlight adjustment. P01.04 – Delay before switching to low display backlight.
  • Page 7 L1-L2-L3 L3-L2-L1 P02.01 – Value for current transformer primary. Example: with 800/5 set 800. P02.02 – Value for phase current transformer secondary. Example: with 800/5 set 5. OFF= no display of the current. P02.03 – Use of voltage transformers (VT) on the generator voltage measuring inputs. P02.04 –...
  • Page 8 P07.01 - Selection of source from which engine speed measurement is obtained. OFF = speed not measured or displayed. Freq. Gen = RPM calculated from frequency of generator. Rated frequency corresponds to rated speed. W / Pick-up = RPM calculated from the frequency of the W/Pick-up/AC signal from the permanent magnet battery charging alternator, referred to the RPM/W (Pick-up) ratio set in the next parameter.
  • Page 9 P10.01 - Specifies the source of the fuel level measurement. OFF = analog measurement not used. The INP1 terminal is used as programmable digital input. INP1 = measurement taken from resistive sensor with analog input to INP1 terminal. AN2 – AN3 = measurement taken from the analog inputs of the optional expansion module EXP1040.
  • Page 10 P12 – GENERATOR VOLTAGE CONTROL Default Range P12.01 MIN voltage threshold 70-100 P12.02 MIN voltage delay 0-600 P12.03 MAX voltage threshold 100-130 / OFF P12.04 MAX voltage delay 0-600 P12.05 Delay for return of generator within thresholds 1-9999 P12.06 MIN/MAX threshold hysteresis 0.0-5.0 P12.07 MAX asymmetry threshold...
  • Page 11: Programmable Input Functions

    P17 - MISCELLANEOUS Default Range P17.01 Maintenance interval OFF/1-99999 P17.02 Rental hours pre-set OFF/1-99999 P17.03 Maximum kVA alarm threshold OFF/5-250 P17.04 Maximum kVA alarm delay 0-9999 P17.05 Generator switch feedback delay 1-60 P17.01 – This defines the programmed maintenance interval, expressed in hours. If set to OFF, the maintenance interval is deactivated. P17.02 –...
  • Page 12: Alarms

    Starter motor Energise starter motor. Fuel solenoid valve Energise the fuel solenoid valve. Global alarm Output activated in the presence of any alarm with the Global alarm property activated. Mechanical fault Output activated if at least one alarm with this property is enabled. Electrical fault Output activated if at least one alarm with this property is enabled.
  • Page 13: Alarm Table

    System error (5V) Occurs if an internal error occurs in the RGK4...SA controller. Contact Technical Support. Rental time finished Occurs when rental hours reach zero. Use the Commands menu to reset rental hours and reset the alarm. Radiator coolant low. Occurs if the coolant level falls below the minimum.
  • Page 14: Installation

    Installation  The RGK4...SA controller is designed to be flat panel mounted. With correct installation and the optional seal, the RGK400SA controller achieves a front protection rating of IP65.  Insert the controller in the hole in the panel, making sure that the seal, if present, is correctly positioned between the panel and controller's casing.
  • Page 15: Connection Diagrams

    Connection diagrams Generic connection diagram for three phase generating sets with pre-excited battery charging alternator 21 20 RGK400SA RGK420SA 13 14 3 4 5 Connection diagram for single phase generating sets Connection diagram for two phase generating sets 21 20 21 20 Doc: I470GB10_16.docx...
  • Page 16: Terminal Layout

    Connection diagram for generating sets with speed detection by pick-up INP1 used as digital input 18 19 3 4 5 Connection diagram for generating sets with permanent magnet battery charger 18 19 C.B. REG. Doc: I470GB10_16.docx 18/10/2016 p. 16 / 19...
  • Page 17: Mechanical Dimensions And Panel Cut-Out

    Layout of terminals S.GND INP1/AN INP2 INP3 INP4 INP5 +COM1 OUT1 OUT2 OUT3 OUT4 OUT5 +COM2 Physical dimensions RGK400SA RGK420SA Panel holes Doc: I470GB10_16.docx 18/10/2016 p. 17 / 19...
  • Page 18: Technical Characteristics

    Operating range 7.5…33 V= Minimum starting voltage 4.5 V= Current in OFF mode – INP6 closed <50 mA at 28 V= (RGK400SA only) Current in OFF mode <20 μA at 28 V= Digital inputs: terminals 3 - 6 Input type negative Input current 6 mA...
  • Page 19: Manual Revision History

    Use 60°C/75°C copper (CU) conductor only AWG Range: 18 - 12 AWG stranded or solid Field Wiring Terminals Tightening Torque: 4.5 lb.in Flat panel mounting on a Type 1 or 4X enclosure (RGK400SA only) Manual revision history Date Notes 21/05/2016 First revision Doc: I470GB10_16.docx...

This manual is also suitable for:

Rgk420sa

Table of Contents

Save PDF