ScRolling HElP TExT in DiSPlay linE 3

[01]
Set correct password
[02]
Enter advanced setup menu?
[03]
Select current input
Select voltage input
[04]
Select 0..20 mA input range
Select 4..20 mA input range
Select -10..10 mA input range
Select -20..20 mA input range
[05]
Select 0.0..1 V input range
Select 0.2..1 V input range
Select 0..5 V input range
Select 1..5 V input range
Select 0..10 V input range
Select 2..10 V input range
Select -1..1 V input range
Select -5..5 V input range
Select -10..10 V input range
[06]
Select display unit
[07]
Select decimal point position
[08]
Set display range low
[09]
Set display range high
[10]
Select current as analog output type
Select voltage as analog output type
[11]
Select 0...20 mA output range
Select 4...20 mA output range
Select 4...20 mA with safety readback
Select -10...10 mA output range
Select -20...20 mA output range
[12]
Select 0.0...1 V output range
Select 0.2...1 V output range
Select 0...5 V output range
Select 1...5 V output range
Select 0...10 V output range
Select 2...10 V output range
Select -1...1 V output range
Select -5...5 V output range
Select -10...10 V output range
[13]
Select active output mode
Select passive output mode
[14]
Select no error action - output undefined at error
Select downscale at error
Select zero output at error
Select upscale at error
[15]
Set Analog output response time in seconds
[16]
Select Analog output function
Enter Language setup
Enter Password setup
Enter Simulation mode
Perform Process calibration
Enter Display setup
Perform Memory operations
[17]
Load saved configuration into module
Save configuration in display front
[18]
Adjust LCD contrast
[19]
Adjust LCD backlight
[20]
Write a 6-character device TAG
[21]
Analog output value is shown in display line 3
Device TAG is shown in display line 3
[22]
Calibrate Input low to process value?
[23]
Set value for low calibration point
[24]
Calibrate Input high to process value?
[25]
Set value for high calibration point
[26]
Use process calibration values
[27]
Enable simulation mode?
[28]
Set the input simulation value
[29]
Enable password protection?
[30]
Set new password
[31]
Select language
[32]
Select direct output mode
Select inverted output mode
Select V-function output mode
[33]
Display underrange
[34]
Display overrange
[35]
Input underrange
[36]
Input overrange
[37]
Analog output supply error
[38]
Analog output error
- check output connections and reset power
[39]
Configuration error
- default configuration is loaded
[40]
RAM memory error
[41]
EEprom memory error
[42]
A/D converter error
[43]
No communication
[44]
Loop error
[45]
Invalid configuration type or version
[46]
External flash error
[47]
Internal flash error
41 0 4 V 1 0 0 - UK