Dell PowerEdge R830 Owner's Manual page 49

Hide thumbs Also See for PowerEdge R830:
Table of Contents

Advertisement

Option
Description
External Serial
Enables you to associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote
Connector
Access Device by using this option.
Failsafe Baud Rate
Specifies the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate
automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed.
This option is set to 115200 by default.
Remote Terminal
Sets the remote console terminal type. This option is set to VT 100/VT 220 by default.
Type
Redirection After
Enables or disables the BIOS console redirection when the operating system is loaded. This option is set to
Boot
Enabled by default.
Related links
Serial Communication
Viewing Serial Communication
System Profile Settings
You can use the System Profile Settings screen to enable specific system performance settings such as power management.
Related links
System Profile Settings details
System BIOS
Viewing System Profile Settings
Viewing System Profile Settings
To view the System Profile Settings screen, perform the following steps:
1.
Turn on, or restart your system.
2.
Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then
restart your system and try again.
3.
On the System Setup Main Menu screen, click System BIOS.
4.
On the System BIOS screen, click System Profile Settings.
Related links
System Profile Settings
System Profile Settings details
System Profile Settings details
The System Profile Settings screen details are explained as follows:
Option
Description
System Profile
Sets the system profile. If you set the System Profile option to a mode other than Custom, the BIOS
automatically sets the rest of the options. You can only change the rest of the options if the mode is set to
Custom. This option is set to Performance Per Watt Optimized (DAPC) by default. DAPC is Dell Active
Power Controller.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by
SOL, configure the same port address for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The
serial MUX setting can independently be changed in iDRAC. Loading the BIOS default settings
from within the BIOS setup utility may not always revert this setting to the default setting of Serial
Device 1.
49