Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied
by the manufacturer.

Connection with natural gas

The connection pressure for natural gas is 1.74 kPa.
THIS APPLIANCE IS EQUIPPED FOR NATURAL (PROPANE) (LP) GAS
This appliance is equipped with orifices sized for operation with natural (PROPANE) (LP) gas.
For conversion to LP (propane) (natural) gas see instruction plate on the appliance.
Orifices necessary for LP (propane) (natural) conversion are provided .*
Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied
by the manufacturer.
CP-94G
Nominal
Reduced
input
input
47600 Btu/h
16400 Btu/h
14 kW
4.8 kW
* Unscrewed for about one turn + 1/2 turn.
** Screwed fully down.
CP-98G
Nominal
Reduced
input
input
95200 Btu/h
32800 Btu/h
28 kW
9.6 kW
* Unscrewed for about one turn + 1/2 turn.
** Screwed fully down.
NOTE: GAS A = Natural gas
NOTE: GAS E = Propan gas
RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS
Our appliances are tested and regulated with liquid gas (see data plate).
The conversion or adaptation to another type of gas must be carried out by a specialised technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see "burners" technical data table).
SUBSTITUTING THE NOZZLE IN THE MAIN BURNER
Remove the front fixing screws from the panel, remove the start-up cable from the piezoelectric ignition device
Using a suitable spanner, unscrew the nozzle and substitute it with the right one (see the technical data table).
SUBSTITUTING THE NOZZLE IN THE PILOT BURNER
The flame of the pilot burner has fixed air.
The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.
Important!
After having carried out the conversion to another type of gas, it is necessary to update the data plate, indicating the
type of gas for which the appliance has been converted.
The appliance contains the instructions necessary for use.
Check the appliances for gas leaks.
USA
"BURNERS" TECHNICAL DATA TABLE
Primary air
Main burner injector
setting
GAS A: open
GAS A: 3.50mm (Ø)
GAS E: open
GAS E: 2.05mm(Ø)
Primary air
Main burner injector
setting
GAS A: open
GAS A: 3.50mm (Ø)
GAS E: open
GAS E: 2.05mm(Ø)
(pressure at the outlet of the regulator)
(pressure at the outlet of the regulator)
CHECKING FUNCTIONING
Pilot burner injector
GAS A: 0.62 mm (Ø)
GAS E: 0.30 mm (Ø)
Pilot burner injector
GAS A: 0.62 mm (Ø)
GAS E: 0.30 mm (Ø)
= 10 mbar (4 inch water)
= 24.9 mbar (10 inch water)
10
By-pass screw
GAS A: 1.25 mm(Ø)*
GAS E: 1.25 mm(Ø)**
By-pass screw
GAS A: 1.25 mm(Ø)*
GAS E: 1.25 mm(Ø)**