ACT ACTpro Operating And Installation Instruction

120e single door station with 12v dc 2a power supply

Advertisement

pro
ACTpro 120e Single Door Station
with 12V DC 2A power supply
Operating and
Installation Instructions
ACT Product Code: ACTpro 120e

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTpro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ACT ACTpro

  • Page 1 ACTpro 120e Single Door Station with 12V DC 2A power supply Operating and Installation Instructions ACT Product Code: ACTpro 120e...
  • Page 2 ACTpro 120e PSU Operating and Installation Manual ACTpro 120e PSU Installation Guide The ACTpro 120e is a single door station with an integrated 12V DC 2A power supply. It expands any of the existing ACTpro controllers (ACTpro 4000, 4200, 1520e, 1500e) by one door.
  • Page 3 ACTpro 120e PSU Operating and Installation Manual Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0...
  • Page 4: Dip Switch Addressing

    ACTpro 120e PSU Operating and Installation Manual DIP Switch Addressing: Door 1 is reserved for the ACTpro 1520e/1500e controller Door 1 & 2 are reserved for all other ACTpro controllers (ACTpro 4200, 4000, 3200, 3000, 2000) Required Address Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0...
  • Page 5 For Wiegand Entry Readers wire D0 to DATA Pin on ACTpro Door Station and D1 to CLOCK pin on ACTpro Door Station. For Wiegand Exit readers wire the D0 of the exit reader to SENSE pin on ACTpro Door Stationand D1 to CLOCK pin on ACTpro Door Station.
  • Page 6 Comms Offline: Door station is offline. Mains Fault: ACTpro 100e Door Station will accept a mains present signal from a PSU (pre-wired on ACTpro 120e). This is wired into MAINS PRESENT input on the PCB. When the PSU has no mains supply the fault is active.
  • Page 7: Installation Instructions

    ‘Power Budget’ for more information. Installation Instructions The ACTpro 120e Door Station is for indoor installation only and must be installed as permanently connected equipment. An external mains disconnect device must be fi tted. Before installation ensure that the mains supply to the ACTpro 120e Door Station is disconnected.
  • Page 8: Battery Insertion

    ACTpro 120e PSU Operating and Installation Manual Mains Power up Attach a correctly rated mains cable and fasten using the cable tie. Use an approved external mains disconnect device. Apply mains power. Check the ‘AC OK’ LED is on and measure the +12V output.
  • Page 9 Mains present The PSU MAINS PRESENT output is pre-wired to the MAINS PRESENT input of the ACTpro 120e door station. Output Voltage The PSU output voltage level is reported to the ACT Enterprise software and on the web browser. Tamper The enclosure lid is tamper monitored.
  • Page 10: Door Contact (Dc)

    ACTpro 120e PSU Operating and Installation Manual Push Button (PB) PUSH TO EXIT Push button is connected between PB input and 0V. When push button is pressed the main relay is activated for the NC C NO confi gured time.
  • Page 11: Ordering Information

    Controller ACTpro 1520e controller with integrated 12V DC 2A power supply ACTpro 1500e Single door IP controller expandable to 32 doors with ACTpro door stations ACTpro 100e Single door station ACTpro 120e ACTpro 100e door stations with integrated 12V DC 2A power supply...
  • Page 12 This manual refers to the ACTpro 120e door station with an integrated 12V DC 2A power supply. Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.