ACTpro 120e Features and Specification:
Features:
Main relay and AUX relay
Supports all ACTpro readers (RFID 125KHz, MIFARE Classic, DESFire EV1)
Break glass monitoring
Voltage monitoring
Supports Clock and Data or Wiegand readers
Multiple entry & exit readers
Reader current limiting / short circuit protection
Request to exit
Door monitoring
Tamper and mains present monitoring
Status LED's
Interlocking
Technical Details:
Relay contact rating
Indoor use only
Compatible with all ACTpro Controllers
PSU Output Voltage:
12V DC
The power supply provides two 12V outputs. One pre-wired to power
the ACTpro Door station. Second is available to power locks.
The full load current shared between the two outputs, ACT recommend
that a maximum of 1.5A is used to power locks and readers. The
remaining 0.5A is used by the door station and battery charging.
Total current from both outputs must not exceed 2A.
Monitoring:
Mains present
The PSU MAINS PRESENT output is pre-wired to the MAINS PRESENT
input of the ACTpro 120e door station.
Output Voltage The PSU output voltage level is reported to the ACT Enterprise software
and on the web browser.
Tamper
The enclosure lid is tamper monitored.
Note:
All faults including Mains Present and Tamper are reported on ACT
Enterprise and via the web browser on the ACTpro 1520e controller.
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
ACTpro 120e PSU Operating and Installation Manual
Main relay 5A / 50 Vac, AUX relay 1A / 50 Vac