ACT ACTpro Operating And Installation Instruction page 5

120e single door station with 12v dc 2a power supply
Table of Contents

Advertisement

Wiring of entry & exit readers.
Reader
Recommended
Terminal
wiring colour
Block
SENSE
White
CLOCK
Green
DATA
Blue
+12V
Red
0V
Black
RED
Brown
GREEN
Yellow
For Wiegand Entry Readers wire D0 to DATA Pin on ACTpro Door Station and D1 to
CLOCK pin on ACTpro Door Station.
For Wiegand Exit readers wire the D0 of the exit reader to SENSE pin on ACTpro Door
Stationand D1 to CLOCK pin on ACTpro Door Station.
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
ACTpro 120e PSU Operating and Installation Manual
Entry Reader
ACTpro 1050e
Pin & Proximity Reader
Exit Reader
(Do not connect to SENSE)
ACTpro 1030e
Proximity Reader
Controller
Signal information
input Pin
SENSE
For Entry readers connect the reader SENSE cable or
terminal to the SENSE input pin.
For Exit readers, do not use this input.
CLOCK
This is the clock or strobe signal input on the ACTpro
120e. Connect the reader CLOCK cable or terminal
on the reader to CLOCK input pin.
DATA
This is the Data input.
Connect the reader DATA cable or terminal on the reader
to DATA input pin.
+12V
Positive +12V DC Supply voltage for the reader.
0V
0V Supply Voltage for the reader.
RED
Red LED control output from the ACTpro 120e.
Connect the reader brown cable to the terminal marked
RED on the door station.
GREEN
Green LED control output from the ACTpro 120e.
Connect the reader green cable or terminal marked
GREEN on the ACTpro Door Station.
SENSE
CLOCK
DATA
+12V
OV
RED
GREEN
4