GE KVGC 202 Technical Manual page 20

Voltage regulating control
Table of Contents

Advertisement

KVCG202/EN M/H11
Cell
Text
000D
Ctrl Status
000E
Grp now
000F
LSB Stage
0011
Software
0020
Log Status
0021
Rly Status
0022
Alarms
0
Uncfg
1
Uncalib
2
Setting
3
No Service
4
No Samples
5
No Fourier
6
Test Wdog
0002 SYS Password [PWP]
The selected configuration of the relay is locked under this password and cannot be
changed until it has been entered. Provision has been made for the user to change the
password, which may consist of four upper case letters in any combination. In the event
of the password becoming lost a recovery password can be obtained on request, but the
request must be accompanied by a note of the model and serial number of the relay.
0003 SYS Function Links [PWP]
These function links enable selection to be made from the system options.
0004 SYS Description [PWP]
This is text that describes the relay type. It is password protected and can be changed by
the user to a name which may describe the scheme configuration of the relay if the relay
is changed from the factory configuration.
0005 SYS Plant Reference [PWP]
The plant reference can be entered by the user, but is limited to 16 characters.
This reference is used to identify the primary plant with which the relay is associated.
0006 SYS Model Number [READ]
The model number that is entered during manufacture has encoded into it the mechanical
assembly, ratings and configuration of the relay. It is printed on the frontplate and should
be quoted in any correspondence concerning the product.
0008 SYS Serial Number [READ]
The serial number is the relay identity and encodes also the year of manufacture.
It cannot be changed from the menu.
0009 SYS Frequency [SET]
The set frequency from which the relay starts tracking on power-up.
000A Communication Level [READ]
This cell will contain the communication level that the relay will support. It is used by
master station programs to decide what type of commands to send to the relay.
000B SYS Relay Address [SET]
Status
Description
READ
Binary word used to indicate the status of control data
READ
Indicates the active setting group
READ
Indicates the last received load shedding command
READ
Software reference for the product
READ
Indicates the current status of all the logic inputs
READ
Indicates the current status of the output relay drives
READ
Indicates the current state of internal alarms
READ
Error in factory configuration settings
READ
Operating in uncalibrated state
READ
Error detected in stored settings
READ
Out-of-service and not functioning
READ
No A/D samples but still in service
READ
Fourier is not being performed
SET
Test watchdog by setting this bit to "1"; 0 = normal