Safety Considerations
Nailor assumes the responsibility for providing you a safe product and safety guidelines during its use. Safety means protection to
all individuals who install, operate, and service the equipment as well as protection of the equipment itself. To promote safety, we
use hazard alert labeling in this manual. Follow the associated guidelines to avoid hazards.
DANGER represents the most severe hazard
alert. Bodily harm or death will occur if danger
guidelines are not followed.
WARNING represents hazards that could result
in severe injury or death.
CAUTION indicates potential personal injury or
equipment or property damage if instructions
are not followed.
Note: Notes provide additional information that is important.
Tip: Provides programing tips and shortcuts that may save time.
Section 2: Installing the Controllers
This section provides important instructions and guidelines for installing the Nailor EZvav controllers. Carefully review this
information before installing the controller.
Installing Nailor EZvav includes the following topics that are covered in this section.
Installation topics in this section
Setting the rotation limits ...................................................................................................................7
Mounting on a VAV terminal box ........................................................................................................8
Connecting an airflow sensor .............................................................................................................9
Connecting inputs and outputs ..........................................................................................................9
Connecting room temperature sensors ..............................................................................................9
Connecting a DAT sensor ..................................................................................................................10
Connecting power.............................................................................................................................10
Maintenance .....................................................................................................................................10
Setting the Rotation Limits
Nailor EZvav controllers are manufactured for a damper that rotates 90 degrees from open to close. If the VAV damper is not a 90
degree damper, set the rotation limits to 45 or 60 degrees before mounting the controller.
CAUTION Setting rotation limits that do not
match the VAV damper may result in improper
operation or equipment damage.
Date: 10-2016
Supersedes: 7-2016
Nailor reserves the right to change any information concerning product or specification without notice or obligation.
Installation and Operation Manual
Page 7 of 48
EZvav Digital Controls
IOM-EZVAVINST

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bac-8005-36Tsp-8001-36Bac-8007-36

Table of Contents