Wiring Diagram - Shop fox W1849 Owner's Manual

14" resaw bandsaw
Table of Contents

Advertisement

ON/OFF Switch
(viewed from behind)
ON/OFF Switch
KEDU HY56
U
R
V
S
P
O
T
S
Ground
S
V
U
Rewired for 220V
U V
Ground
1
4
3
2
Wiring.Diagram
˚
R
110 VAC
5-15 Plug
Neutral
Hot
Ground
Rewired for 220V
U V
3
2
1
4
Ground
-76-
Model W1849 (For Machines Mfd. Since 11/16)
WARNING!
UNEXPECTED INJURY ˚
HAZARD!
Disconnect machine from
power before changing
cutting tools or perform-
ing maintenance.
Capacitor
Start
Capacitor
Figure 113. Motor electrical components.
Hot
220
VAC
Hot
G
Ground
(As Recommended)
START
CAPACITOR
200 MFD
250 VAC
RUN
CAPACITOR
50 MFD
250 VAC
Read
Page 75
STOP
Before
Wiring
Run
Motor
Junction
Box
220 VAC
6-15 Plug
MOTOR

Advertisement