Final Check - Hamlet SOLUTION Operating & Installation Manual

Smoke control stoves
Table of Contents

Advertisement

INSTALLATION
Procedure for fitting throat plate assembly.
This must be carried out with the wood burning
tray and side liners removed.
All images below are cut-away for clarity
1.
Insert throat plate assembly into the fire box
and manoeuvre so that the throat plate
drops into the landing plate cut-outs,
See fig 3
Fig. 3. Throat plate in landing cut-outs
2. Raise the throat plate assembly vertically out of
the landing slots ensuring the front edge remains
Behind the front edge of the Air Entry lip,see fig 4
3. hook the throat plate „T‟ cut-out onto the support
hanger and push back to slide onto the
secondary air tube, the wood tray will hold the
bottom edge into the correct position.
Fig. 4. Throat Plate support and
Secondary air pipe
Hamlet Solution Stoves
Throat plate in
landing plate
cut-outs
TP support hanger
and air pipe
Air entry lip
Fig. 5. Throat plate in correct position
FINAL CHECK LIST
Before handing over the installation to the
customer it is a requirement under Document J
that the appliance is lit and the functioning of the
chimney system is checked for satisfactory
operation.
Be sure that the chimney is operating
and ALL smoke and fumes are vented to
the atmosphere through the chimney
terminal.
Check all joints and seals.
Clean the outside of the appliance to
prevent any stains becoming burnt on.
Check the flue draught which should
read 1—2mm, or 0.1—0.2 mbar.
If Building Control Consent route is being
sought please complete the check list on
page 17.
For a registered Competent Persons
Scheme, such as HETAS, please
complete the Certificate Of Compliance,
which is used for checking and reporting
the installation as imposed by the
Government
Explain the controls and operation of the
appliance to the customer.
The following details must be checked and
completed in full by the installer at the time of
installation. Please answer all questions as fully as
possible. Hamlet stoves cannot be held
responsible for the chimney or installation.
15