Hamlet Hereford Operating & Installation Manual

Wood/multifuel stoves

Advertisement

Operating & Installation Manual
Hereford
Wood/Multifuel Stoves
Hereford 7 Flat Multifuel Stove
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
Rev 1
August 2004
Part No. AFS1176

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hereford and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hamlet Hereford

  • Page 1 Operating & Installation Manual Hereford Wood/Multifuel Stoves Hereford 7 Flat Multifuel Stove PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Rev 1 August 2004 Part No. AFS1176...
  • Page 2 Congratulations on your choice of Hamlet Stove. More than 20 years experience has been put into the development of our Hereford Family to ensure ultimate performance and years of trouble free enjoyment. Every detail on the fire has been carefully engineered and designed which is why we are so confident in the reliability of our product.
  • Page 3: Table Of Contents

    Final Installation Check List Fuel Types Parts List 24-25 Lighting The Fire GUARANTEE Extended Burning 11-12 1 Year Guarantee Ash Removal Customer Registration Over Firing SERVICE RECORD Service Record SERVICING Final Factory Check List Cleaning Annual Maintenance Hereford Wood/Multifuel Stoves...
  • Page 4 TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www.solidfuel.co.uk THE USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY ARADA LTD WILL INVALIDATE THE APPLIANCE GUARANTEE. Hereford Wood/Multifuel Stoves...
  • Page 5: Introduction

    • Use gloves to provide additional grip. controlled by the air inlet mechanism. Hamlet Stoves are also fitted with an "air wash" so called because it provides a curtain of high speed THE PRINCIPLE OF THE FIRE preheated air behind the glass to help keep it clean and to provide secondary air/over draught.
  • Page 6: Check List

    2. Cast fire door handle 3. Throat plate 4. Flue spigot 1 (5”) 1(5”) 5. Hotplate 1 (5”) 1(5”) 6. Ashpan 7. Operating tool 8. Rear liner 9. Side liners 10. Feet and Fixings 11. Operating Manual Hereford Wood/Multifuel Stoves...
  • Page 7: Technical Data

    Height (mm) Width (mm) Depth (mm) Height to Centre of Rear Flue Depth from Back to Centre of Flue (mm) 127 (5”) 127 (5”) 127 (5”) 127 (5”) 127 (5”) Flue Diameter 127 (5”) Weight Packed (Kg) Hereford Wood/Multifuel Stoves...
  • Page 8: Operating Instructions

    DISASSEMBLE AIRWASH specially shaped throat plate which sits on the The Hereford air wash may be disassembled for liners. If these are not in place please refer to page cleaning or adjustment. To achieve this, the 15 to install these.
  • Page 9: Fire Door Glass

    (Fig.8) Re-place the doors carefully over the hinges and slot in place. Fig. 5 Removal of the Hereford 10 door •Unscrew the two nuts, on the inside of the door securing the retaining clips.
  • Page 10: Fitting The Feet

    FITTING THE FEET Coal - Household coal produces a large amount of The Hereford wood and multifuel stoves must be ash and smoke. If used the appliance and chimney fitted with the feet supplied. will require frequent cleaning. Therefore soft house coal is not recommended.
  • Page 11: Lighting The Fire

    •Set the primary inlet to the fully open position glow brightly and place pieces of fuel on the fire •Light in the normal manner with paper and until it is well established. kindling, or use a fire lighter. Hereford Wood/Multifuel Stoves...
  • Page 12: Ash Removal

    Further de-ashing will cause heat build-up under the grate, which will considerably shorten its life. Hereford Wood/Multifuel Stoves...
  • Page 13: Annual Maintenance

    Hamlet dealer. With a wire brush clean inside OUTER FINISH the appliance paying particular attention to the...
  • Page 14: Installation

    To make movement easier internal fittings, grates, fan to either of these rooms is not recommended. firebox liners, flue outlets, hot plate, throat plate, etc., can be removed. Care should be taken to make sure that the hinges are not damaged during installation. Hereford Wood/Multifuel Stoves...
  • Page 15: Firebox Liner Panels

    •With the grate in place •Insert the side liner panels Fig. 11 Liners inserted in Hereford 7 wood/ •Set the small liners into the back of the fire resting multifuel stove. onto the ledge behind the grate.
  • Page 16: Interchangeable Canopies

    They are fitted as follows: (Fitting Low/High Versions) •To fit the interchangeable canopy (Fig 10c): The canopy versions for the Hereford 7 & 10 •Remove the front clamps. range is a flat top stove to which a low or high •Tilt the canopy as shown in stage 1.
  • Page 17: Flues & Chimneys

    Factory made insulated chimney complying with BS 4543: Part 2 (often called "Class 1 prefabricated metal chimney"). These types of chimney should be installed in accordance with the Building Regulations and BS 7566: Parts 1 to 4. Hereford Wood/Multifuel Stoves...
  • Page 18 England and Wales is available from The Stationery Engineer): telephone 0800 0924019 Bookshops also www.nace.org.uk viewed ODPM website www.safety.odpm.gov.uk/bregs/brads.htm NACS (National Association of Chimney Sweeps): telephone 01785 811732 Details on the relevant Building Regulations and www.chimneyworks.co.uk BS British Standards are given in the "General Hereford Wood/Multifuel Stoves...
  • Page 19 INSTALLATION Hereford Wood/Multifuel Stoves...
  • Page 20 BS7566 P WITH BUILDING REGULATIONS AND IEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non-insulated flue = 1.5 x D to a non-combustible surface/material 3 x D to combustible surface/material Hereford Wood/Multifuel Stoves...
  • Page 21: Add In Boilers/Water Connections

    In many cases your supplier will be able to offer advice and assistance. Hereford wood/multifuel stoves offer the option of a slab boiler, which occupies the position of the rear Direct Systems firebox liner panels.
  • Page 22: Final Check

    What is the height and distance of the hot water tank above the stove? A checklist (Pre-lighting Checks) appears in the Operating Instructions, but in addition to this the installer should: Hereford Wood/Multifuel Stoves...
  • Page 23: Final Installation Check List

    I/we the undersigned confirm that the above details are correct. In my opinion, these works comply with the relevant requirements in Part J of Schedule 1 to the Building regulations. Print name and title....................Profession................Capacity........................Telephone................Address................................Post code........Signed......................Date......... Registered membership of..(e.g. CORGI, OFTEC, HETAS, NACE, NACS)..........Hereford Wood/Multifuel Stoves...
  • Page 24: Parts List

    5. Hot Plate AFS009 AFS009 6. Operating Tool AFS008 AFS008 7. Ashpan AFS058 AFS050 8. Flue Spigot AFS010 AFS010 9. Anthracite Spray Paint AFS101A AFS101A 10. Hamlet Fire Gloves AFS998 AFS998 11. Replacement AFS1176 AFS1176 operating Manual Hereford Wood/Multifuel Stoves...
  • Page 25 AFS1021 AFS1021 20. Main door Left hand door Left hand door assembly complete AFS1174 complete AFS1180 complete with handle, glass, Right hand door Right hand door gaskets, clips and complete AFS1175 complete AFS1181 seal Hereford Wood/Multifuel Stoves...
  • Page 26: Guarantee

    Hamlet fire. If you think your fire is not working correctly or in When you buy an Hamlet Stove, you are not only the case of a breakdown, please call your local buying a first class appliance - you are buying a...
  • Page 27: Service Record

    Work Carried Out Signature Date of Visit Should you have any questions about your Hereford wood/multifuel Stove that is not covered in this manual please contact your Hamlet retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
  • Page 28: Final Factory Check List

    FINAL FACTORY CHECK LIST Model........Serial No......QUALITY FINISH I’ve checked it PARTS and it’s O.K. FLUE OUTLET HOT PLATE FIREBOX LININGS GRATE Assembled by......THROAT PLATE AIR WASH Checked by ........ DOOR CATCHES FEET & FIXINGS ASH PAN OPERATING TOOL OPERATING INSTRUCTIONS Please ensure the enclosed registration card is completed and returned to Arada Ltd and the following information completed for your own information.