Operating & Installation Manual SOLUTION RANGE OF SMOKE CONTROL STOVES PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK123 Rev 02 February 2011 EN 13240:2001+ Part No. AFS 1535 Amd. A2:2004...
Page 2
Should you have any questions about our Solution stoves that are not covered by this manual, please contact the Hamlet retailer in your area, or call our technical support department on 0844 847 5107.
Final Check Over Firing & Chimney Fires Building Control Consent Checklist Ash Removal Air Inlet Control Multi Purpose Operating Tool Main Fire Door Handle OPTIONAL EXTRA/ACCESSORIES SPARE PARTS LIST 29-30 GUARANTEE 31-32 GENERAL DIMENSION DRAWING FACTORY CHECK LIST Hamlet Solution Stoves...
MUST NOT BE BURNED IN THIS APPLIANCE BITUMINOUS HOUSE COAL SHOULD NEVER BE USED IN YOUR STOVE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE. IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0845 601 4406 www.solidfuel.co.uk Hamlet Solution Stoves...
Avoid twisting at the waist. It is better to Hamlet stoves are also fitted with an „air wash‟ reposition your feet. so called because it provides a curtain of high ...
Some models may be despatched with the flue spigot inside the stove for transportation The flue spigot should be checked to ensure the retaining bolts are fully tightened if the outlet is to remain in the top flue outlet position to avoid the leaking of fumes into the room. Hamlet Solution Stoves...
Data Plate Data Plate Information Location Please Note:- All Solution stoves are fitted with a data plate located on the bottom right hand side of the stove. The data given is that registered on the HETAS website on the output and performance of the stove.
To side of appliance Height (mm) Width (mm) Depth Including control lever (mm) Height To Centre Of Rear Flue (mm) Depth From Back To Centre Of Flue (mm) Flue Diameter (mm) 127 (5”) Weight Packed (Kg) Weight Nett (Kg) Hamlet Solution Stoves...
There must always be a permanent means of providing air for combustion into the room in which All Hamlet stoves contain no asbestos in their the stove is installed. A permanent vent with a total manufacture or construction. If there is a possibility free area of at least 550mm²...
A chimney may comply with regulations but could Spigot still be subject to down draught and similar problems. A chimney terminating above the ridge level is generally less likely to suffer such Fig. 1c. Flue Fitting problems. Hamlet Solution Stoves...
Openings) should be increased by 300 mm the stove to the flue in the chimney and that each KW of rated output. suitable access is provided into the flue for regular inspection and sweeping of the flue ways. Hamlet Solution Stoves...
Page 12
For advice on flues and chimneys contact: NACE (National Association of Chimney Engineers) Telephone : 01526 322555 www.nace.org.uk NACS (National Association of Chimney Sweeps) Telephone : 01785 811732 www.chimneyworks.co.uk HETAS (Official Body To Approve Solidfuel Domestic Heating Appliances) Telephone : 0845 6345626 www.hetas.co.uk Hamlet Solution Stoves...
Page 13
And BS 7566 Part 1 to 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES Combustible Register Thick (Plan View Of Steel Register Plate, 1.5mm Plate. Minimum ) Minimum 1.5mm Thick Steel. TYPICAL TOP FLUE OUTLET (as per BS 8303-1) Hamlet Solution Stoves...
Building regulations require that whenever a new or replacement fixed solid fuel or wood / biomass The Hamlet Solution SC stove uses firebox liner appliance is installed in a dwelling a Carbon panels at both sides of the stove. The throat plate...
Please answer all questions as fully as Fig. 4. Throat Plate support and possible. Hamlet stoves cannot be held Secondary air pipe responsible for the chimney or installation. Hamlet Solution Stoves...
I/We the undersigned confirm that the above details are correct. In my opinion, these works comply with the relevant requirements in part J of Schedule 1 of the Building regulations. Print name and title…………………………………………………………………..Profession………………………………….. Capacity……………………………………………………………………………...Telephone No. …………………………….. Address………………………………………………………………………………………………..Postcode………………….. Signed………………………………………………………………………………..Date………………………………………... Registered member of..(e.g. Gas Safe ( , OFTEC, HETAS, NACE, NACS) CORGI Hamlet Solution Stoves...
NACS chimney engineer who will up heat slowly to gradually cure paint. provide a Certificate Of Chimney Sweeping. Note: Use genuine Hamlet touch up spray as some The whole flue way including the outlet must be paints interact. This could ruin the finish and swept at least twice per burning season.
When the appliance is cold, open the fire door so that it is at right angles to the front of the stove. Lift the fire door up off the hinges. Drop one washer on the top and bottom hinge pins. Hamlet Solution Stoves...
Allow 30 minutes, before refitting the door to the appliance. Refit the door assembly back onto the stove; carefully lift the door over the hinge and slot into place. Rope Gasket Joint Fig. 8. Rope Replacement Fig. 9. Lining Up Gasket Rope Hamlet Solution Stoves...
See image below Fig. 10. Positioning The Glass Slider & Spring retaining bolt Fig. 11. Tightening The Glass Clip Please Note—This should be carried out when the fire is cold and unlit. Air slider viewed from below Hamlet Solution Stoves...
Company Work Carried Out Solution Should you have any questions about your Hamlet Solution stove that are not covered in this manual please contact your Hamlet dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service record chart.
If the installer considers this PLEASE CONTACT : The Manufacturer unavoidable refer to Approved Document J For Further Details & Advice On The Section 1, Paragraphs 1.20 & 1.23 for guidance Use Of Other Fuels. Hamlet Solution Stoves...
OPERATING INSTRUCTIONS CLEAN BURNING OF WOOD The average fuel load of the Solution 5 SC stove is 1.3kg per hour of dry well seasoned hardwood Operation of the air control providing approximately 4.5kwh of heat with the air control set fully to the right stop.
Care must be taken not to risk burning of hands or household objects from falling embers. The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan. Hamlet Solution Stoves...
OPERATING INSTRUCTIONS AIR INLET CONTROLS Air control in Fully open (Ignition) position The Hamlet Solution Smoke Control stoves have only one Air inlet control. The air inlet provides air through the base of the stove, via the control slider located under the front edge of the ash lip.
OPERATING INSTRUCTIONS MULTI PURPOSE OPERATING TOOL Your Hamlet Solution stove is supplied with a multi purpose operating tool, used for adjusting the air inlet controls and the removal of the ash pan ( See fig. 17 ) TO EMPTY THE ASH PAN The Solution stoves are supplied with a unique ash pan.
MAIN FIRE DOOR HANDLE A stove mitten is supplied with your Hamlet Solution stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot.
OPTIONAL EXTRA / ACCESSORIES Hamlet Visual Aid PART DESCRIPTION (not to scale) Sig 5 SC Aerosol Touch Up AFS101A Paint Floor Fixing Kit AFS1135 External Air Duct AFS1536 Flue Spigot (4”) AFS1495 108mm Stove Mitten (Hot AFS1285 Glove) Hamlet Solution Stoves...
Hamlet Visual Aid PART DESCRIPTION (not to scale) Sig 5 SC Throat Plate AFS1494 Flue Spigot (5”) AFS1537 Upper side Liner Set AFS1496 Lower side Liner Set AFS1497 Wood Tray / fuel- AFS1498 retainer Ash Pan AFS058 Hamlet Solution Stoves...
Page 30
AFS047 Hinge & Fixing Kit Fire Door Rope Kit AFS1021 Complete With Glue Fire Door Assembly, AFS1294 Complete Fire Door Handle AFS1222 Assembly Complete Replacement AFS1535 Instructions Canopy flue cut-out cover - For rear flue AFS1529 installations Hamlet Solution Stoves...
FREE OF CHARGE as long as the When you buy an Hamlet stove, you are not stove has been installed according to this only buying a first class appliance you are...
Hamlet stoves gives a Ten Year Guarantee against manufacturing defects of the main body* of its Solution range of stoves. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the item only and does not extend to any other costs, including labour, incurred in its replacement.
Final Factory Check list Stove Model …………….……………… Serial No. ………………………………. I’ve checked it Quality / Finish and its O.K ! Parts Wood Tray - Fuel Retainer Universal Flue Outlet Firebox Liners Throat Plate / Secondary Air Assembled By……………………. Assembly Door Catch / Door Handle Checked by………………………..