Page 1
Operating & Installation Manual SOLUTION RANGE OF STOVES PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Rev 08 BK060 August 2010 Part No. AFS1370 EN 13240:2001+ Amd. A2:2004...
Page 2
Should you have any questions about our Solution stoves that are not covered by this manual, please contact the Hamlet retailer in your area, or call our technical support All Hamlet Solution stoves are approved to European Standard EN 13240 and CE marked.
Final Check Over Firing & Chimney Fires Building Control Consent Checklist Ash Removal Air Inlet Controls Fuel Retainer Bars Multi Purpose Operating Tool Main Fire Door handle OPTIONAL EXTRA/ACCESSORIES SPARE PARTS LIST 29-31 GUARANTEE 32-33 FACTORY CHECK LIST Hamlet Solution Stoves...
MUST NOT BE BURNED IN THIS APPLIANCE BITUMINOUS HOUSE COAL SHOULD NEVER BE USED IN YOUR STOVE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE. IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0845 601 4406 www.solidfuel.co.uk Hamlet Solution Stoves...
Data Plate Information Please Note - All Solution stoves are fitted with a data plate located on the bottom right hand side of the stove. The data given is that registered on the HETAS website on the output and perform- ance of the stove.
Depth (mm) (Inc. Handle) Height To Centre Of Rear Flue (mm) 478.5 Depth From Back To Centre Of Flue 102.5 (mm) Flue Diameter (mm) 102 (4”) 127 (5”) 127 (5”) 152 (6”) Weight Packed (Kg) Weight Nett (Kg) Hamlet Solution Stoves...
13. ASBESTOS AIR FOR COMBUSTION All Hamlet stoves contain no asbestos in their manufacture or construction. If there is a possibility of disturbing any asbestos in the course of the There must always be a permanent means of...
(located on the rear of the appliance) are sealed Building Regulations and BS 7566: Parts 1 to 4. with fire cement, and thus preventing surplus air entering the firebox, resulting in less efficiency and poor fuel consumption. Hamlet Solution Stoves...
Telephone : 0845 6345626 www.hetas.co.uk Details on the relevant Building Regulations and BS British Standards are given in the “ General Precautions” section of these instructions. Chimneys should be as straight as possible. Horizontal runs should be avoided except where Hamlet Solution Stoves...
Page 12
Minimum 150mm (6”) Diameter Flue Maximum 150mm (6”) Horizontal Flue Section Soot Door Fire Retardant Rope Packing Maximum 100mm (4”) Brick Up Aperture Fill Void TYPICAL REAR FLUE OUTLET (as per BS 8303-1) Hamlet Solution Stoves...
Page 13
And BS 7566 Part 1 to 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES Combustible Register Thick (Plan View Of Steel Register Plate, 1.5mm Plate. Minimum ) Minimum 1.5mm Thick Steel. TYPICAL TOP FLUE OUTLET (as per BS 8303-1) Hamlet Solution Stoves...
ADJUSTING THE SELF FIREBOX LINER PANELS LEVELLING FEET The Hamlet Solution stoves use firebox liner panels to the sides and back. The throat plate sits The Hamlet Solution stoves are equipped with on top of the sides and rear panels. These should...
The following details must be checked and completed in full by the installer at the time of installation. Please answer all questions as fully as possible. Hamlet stoves cannot be held responsible for the chimney or installation. Fig. 5. Liners & Throat Plate Correctly Fitted...
I/We the undersigned confirm that the above details are correct. In my opinion, these works comply with the relevant requirements in part J of Schedule 1 of the Building regulations. Print name and title…………………………………………………………………..Profession………………………………….. Capacity……………………………………………………………………………...Telephone No. …………………………….. Address………………………………………………………………………………………………..Postcode………………….. Signed………………………………………………………………………………..Date………………………………………... Registered member of..(e.g. Gas Safe ( ), OFTEC, HETAS, NACE, NACS) CORGI Hamlet Solution Stoves...
It is Note: Use genuine Hamlet touch up spray as some important that the flue ways, flue pipe and chimney paints interact. This could ruin the finish and be cleaned prior to lighting the fire after a invalidate the guarantee.
Lift the fire door up off the hinges. necessary. Drop one washer on the top and bottom hinge Please Note : This operation should only be pins. carried out when the appliance is unlit and cold. Refit the door and check. Hamlet Solution Stoves...
Allow 30 minutes, before refitting the door to the appliance. Refit the door assembly back onto the stove; carefully lift the door over the hinges and slot into place. Joint Rope Gasket Fig. 8. Rope Replacement Fig. 9. Lining Up Gasket Rope Hamlet Solution Stoves...
See Fig 12 Rear of Oval Fig. 11. Tightening The Glass Clip Please Note—This should be carried out when the fire is cold and unlit. Slider Fig. 12. Rear Of Oval / Slider Assembly Hamlet Solution Stoves...
Company Work Carried Out Signature Should you have any questions about your Hamlet Solution stove that are not covered in this manual please contact your Hamlet dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service record chart.
BEFORE LIGHTING THE FIRE. WARNING : NEVER BURN LIQUID FUELS IN ALWAYS WEAR SUITABLE PROTECTIVE FIRE YOUR STOVE. GLOVES WHEN REFUELLING YOUR STOVE. PLEASE CONTACT : The Manufacturer For Further Details & Advice On The Use Of Other Fuels. Hamlet Solution Stoves...
WARNING : when wood is burnt slowly in a closed appliance, it produces moisture and tar, which will create condensation and deposits in the chimney. This effect can be minimised by burning hard for a short period, 15 to 20 minutes, twice a day. Hamlet Solution Stoves...
When the appliance is burning WOOD, it is acceptable to maintain an ash bed on top of the grate bars, of approximately 20mm (3/4”) without any un-due effect upon the grate bars. Hamlet Solution Stoves...
PRIMARY AIR Air enters the appliance through the control on the bottom of the fire door. The Hamlet Solution has a single control knob which slides left to right. Sliding the knob to the right (+), see Fig. 13, will increase the amount of air intake to the stove.
OPERATING INSTRUCTIONS MULTI PURPOSE OPERATING TOOL Your Hamlet Solution stove is supplied with a multi purpose operating tool, used for adjusting the air inlet controls and the removal of the ash pan ( See Fig 17 ) TO EMPTY THE ASH PAN The Solution stoves are supplied with a unique ash pan.
OPERATING INSTRUCTIONS MAIN FIRE DOOR HANDLE The Solution stove is supplied with a ‟Kooler‟ to touch fire door handle. Whilst the spring coiled area of the handle will remain cooler, the attached shaft and fittings will be hot. For this reason we recommend that a suitable glove or mitten is used when the stove is in operation.
100mm. This will effect the height from the floor to the centre of the rear flue outlet, just add 100mm to the stated rear flue outlet, see page 8 for technical information. ** Separate instructions are included for all add in boiler installations. Hamlet Solution Stoves...
Hot Plate AFS009B AFS010 AFS010 AFS012 Rear Liner (s) AFS1207 AFS1210 AFS1213 AFS1244 Side Liners AFS1209 AFS1212 AFS1243 AFS1206 AFS1205 AFS1208 AFS1211 AFS1242 Liner Set Ash Pan AFS058 AFS050 AFS1309 AFS1391 Fuel Retainer AFS1190 AFS1192 AFS1191 AFS1240 Hamlet Solution Stoves...
Page 30
Hinge & Fixing Kit Fire Door Rope Kit AFS1021 AFS1021 AFS1021 AFS1021 Complete With Glue Fire Door Assembly, AFS1294 AFS1295 AFS1311 AFS1311 Complete Fire Door Handle Assembly AFS1222 AFS1222 AFS1222 AFS1222 Replacement AFS1370 AFS1370 AFS1370 AFS1370 Instructions Hamlet Solution Stoves...
FREE OF CHARGE as long as the When you buy a Hamlet stove, you are not only stove has been installed according to this buying a first class appliance you are buying a...
Hamlet stoves gives a Ten Year Guarantee against manufacturing defects of the main body* of its Solution range of stoves. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the item only and does not extend to any other costs, including labour, incurred in its replacement.
Final Factory Check list Stove Model …………….……………... Serial No. ……………………………….. Quality / Finish I’ve checked it Parts and its O.K ! Wood Burning Tray Flue Outlet Hot Plate Assembled By……………………….. Fuel Retainers Firebox Liners Checked by…………………………... Throat Plate Air Wash Door Catch / Kool Touch Door Handle Ash Pan Adjusting Feet x2...
Need help?
Do you have a question about the Solution and is the answer not in the manual?
Questions and answers