INSTALLATION
CO ALARM
Building regulations require that whenever a new
or replacement fixed solid fuel or wood / biomass
appliance is installed in a dwelling a Carbon
Monoxide Alarm must be fitted in the same room
as the appliance. Further guidance on the
installation of the CO Alarm is available in
BS EN 50292:2002 and from the alarm
manufacturers instruction.
Provision of an alarm must not be considered
a substitute for either installing the appliance
correctly or ensuring regular servicing and
maintenance of the appliance and chimney
system.
ADJUSTING THE SELF
LEVELLING FEET
The Hamlet Solution stoves are equipped with
adjustable rear levelling feet, these are ideal for
use where the hearth surface is not flat or level.
Adjustment is as follows :
Position the stove on the hearth into its final
resting place, ensuring room for the flue
connections etc.
On the rear leg of the stove, loosen the pozi
screw, and rotate the inner „cam‟ shaped
levelling foot until this touches the hearth.
(see fig. 2.)
Re-tighten the pozi screw. Check the stove
is level with a spirit level.
Repeat for the other rear leg.
Fig. 2. Adjusting The Rear Feet
14
FIREBOX LINER PANELS
The Hamlet Solution SC stove uses firebox liner
panels at both sides of the stove. The throat plate
Is not supported by these liners, however the
throat plate must be installed before the liners can
be fitted, and the liners removed before the throat
plate can be removed.
To Removal / fitting the liners
Open the fire door.
Remove the Wood burning tray
Remove the lower side liners, carefully
allowing the upper side liners to slide down
to the landing plate
Remove the upper side liners
Replacing or fitting the liners is the reverse
of this procedure
Note : Cracking of the liner panels does not
effect the normal use or efficiency of the stove.
Throat Plate / Secondary Air Assembly
Upper and lower side liners
Hamlet Solution Stoves