APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 27 of 52)
ADDR
REGISTER NAME
61CC
Percent Differential Target
61CD
Percent Differential Events
61CE
Transformer Inrush Inhibit Mode
Transformer Instantaneous Differential (Read/Write Grouped Setting)
61DA
Inst Differential Function
61DB
Inst Differential Pickup
61DC
Inst Differential Block
61DE
Inst Differential Target
61DF
Inst Differential Events
Breaker Arcing Current Settings (Read/Write Setting) (6 modules)
7290
Breaker 1 Arcing Current Function
7291
Breaker 1 Arcing Current Source
7292
Breaker 1 Arcing Current Initiate A
7294
Breaker 1 Arcing Current Initiate B
7296
Breaker 1 Arcing Current Initiate C
7298
Breaker 1 Arcing Current Delay
7299
Breaker 1 Arcing Current Limit
729A
Breaker 1 Arcing Current Block
729C
Breaker 1 Arcing Current Target
729D
Breaker 1 Arcing Current Events
729E
...Repeated for Breaker 2 Arcing Current
72AC
...Repeated for Breaker 3 Arcing Current
72BA
...Repeated for Breaker 4 Arcing Current
72C8
...Repeated for Breaker 5 Arcing Current
72D6
...Repeated for Breaker 6 Arcing Current
Disconnect (Breaker) Switch (Read/Write Setting) (24 modules)
74A0
Disconnect Switch 1 Function
74A1
Disconnect Switch 1 Name
74A4
Disconnect Switch 1 Mode
74A5
Disconnect Switch 1 Open
74A7
Disconnect Switch 1 Block Open
74A9
Disconnect Switch 1 Close
74AB
Disconnect Switch 1 Block Close
74AD
Disconnect Switch 1 Phase A / Three-pole Closed
74AF
Disconnect Switch 1 Phase A / Three-pole Opened
74B1
Disconnect Switch 1 Phase B Closed
74B3
Disconnect Switch 1 Phase B Opened
74B5
Disconnect Switch 1 Phase C Closed
74B7
Disconnect Switch 1 Phase C Opened
74B9
Disconnect Switch 1 Operate Time
74BA
Disconnect Switch 1 Alarm Delay
74BC
Disconnect Switch 1 Events
74BD
Reserved (2 items)
74BF
...Repeated for Disconnect Switch 2
74DE
...Repeated for Disconnect Switch 3
74FD
...Repeated for Disconnect Switch 4
751C
...Repeated for Disconnect Switch 5
753B
...Repeated for Disconnect Switch 6
755A
...Repeated for Disconnect Switch 7
7579
...Repeated for Disconnect Switch 8
7598
...Repeated for Disconnect Switch 9
75B7
...Repeated for Disconnect Switch 10
75D6
...Repeated for Disconnect Switch 11
75F5
...Repeated for Disconnect Switch 12
GE Multilin
RANGE
0 to 2
0 to 1
0 to 2
0 to 1
2 to 30
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 50000
0 to 4294967295
0 to 2
0 to 1
0 to 1
---
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 65.535
0 to 1
---
T35 Transformer Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F109
---
1
F102
---
1
F189
---
1
F102
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F167
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
2
kA
-cyc
1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F003
---
1
F102
---
---
F001
DEFAULT
0 (Self-reset)
0 (Disabled)
0 (Per phase)
0 (Disabled)
B
8000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
0
0
0
0
1000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
"SW 1"
0 (3-Pole)
0
0
0
0
0
0
0
0
0
0
70
0
0 (Disabled)
0
B-35