GE T35 UR Series Instruction Manual page 423

Transformer protection system
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 9 of 52)
ADDR
REGISTER NAME
User Programmable Fault Report (Read/Write Setting) (2 modules)
3090
Fault Report 1 Fault Trigger
3092
Fault Report 1 Function
3093
Fault Report 1 Prefault Trigger
3095
Fault Report Analog Channel 1 (32 items)
30B5
Fault Report 1 Reserved (5 items)
30BA
...Repeated for Fault Report 2
Modbus File Transfer (Read/Write)
3100
Name of file to read
Modbus File Transfer Values (Read Only)
3200
Character position of current block within file
3202
Size of currently-available data block
3203
Block of data from requested file (122 items)
Security (Read/Write Setting)
3280
Administrator Alphanumeric Password Setting
Security (Read Only)
328A
Administrator Alphanumeric Password Status
Security (Read/Write)
328B
Administrator Alphanumeric Password Entry
Security (Read/Write Setting)
3295
Supervisor Alphanumeric Password Setting
Security (Read Only)
329F
Supervisor Alphanumeric Password Status
Security (Read/Write)
32A0
Supervisor Alphanumeric Password Entry
Security (Read/Write Setting)
32AA
Engineer Alphanumeric Password Setting
Security (Read Only)
32B4
Engineer Alphanumeric Password Status
Security (Read/Write)
32B5
Engineer Alphanumeric Password Entry
Security (Read/Write Setting)
32BF
Operator Alphanumeric Password Setting
Security (Read Only)
32C9
Operator Alphanumeric Password Status
Security (Read/Write)
32CA
Operator Alphanumeric Password Entry
Security (Read/Write Setting)
32D4
Observer Alphanumeric Password Setting
Security (Read Only)
32DE
Observer Alphanumeric Password Status
Security (Read/Write)
32DF
Observer Alphanumeric Password Entry
Security (Read Only)
32E9
Reserved for password settings of future roles (63 items)
3328
Security Status Indicator
Security (Read/Write Setting)
3329
Session Lockout
332A
Session Lockout Period
332B
Reserved
332C
Reserved
332E
Reserved
Security Supervisory (Read/Write Setting)
3331
Local Authentication Enable
GE Multilin
RANGE
0 to 4294967295
0 to 1
0 to 4294967295
0 to 65536
---
---
0 to 4294967295
0 to 65535
0 to 65535
---
0 to 1
---
---
0 to 1
---
---
0 to 1
---
---
0 to 1
---
---
0 to 1
---
0 to 65535
0 to 65535
0 to 99
0 to 9999
0 to 1
0 to 4294967295
1 to 65535
0 to 1
T35 Transformer Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F300
---
1
F600
---
---
F001
---
---
F204
---
1
F003
---
1
F001
---
1
F001
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
1
F202
---
1
F001
---
1
F618
---
1
F001
min
1
F001
---
1
F126
---
1
F003
---
1
F001
---
1
F126
DEFAULT
0
0 (Disabled)
0
0
B
0
(none)
0
0
0
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
0
0
3
3
0 (No)
0
514
1 (Yes
B-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents