1.3 ENERVISTA UR SETUP SOFTWARE
To configure the T35 for remote access via the rear Ethernet port, see the Configuring Ethernet Communications sec-
1
tion.
To configure the T35 for local access with a computer through either the front RS232 port or rear Ethernet port, see the
Using the Quick Connect Feature section.
b) CONFIGURING SERIAL COMMUNICATIONS
Before starting, verify that the serial cable is properly connected to the RS485 terminal on the back of the device. The face-
plate RS232 port is intended for local use and is not described in this section; see the Using the Quick Connect Feature
section.
A computer with an RS232 port and a serial cable is required. To use the RS485 port at the back of the relay, a GE Multilin
F485 converter (or compatible RS232-to-RS485 converter) is required. See the F485 instruction manual for details.
1.
Verify that the latest version of the EnerVista UR Setup software is installed (available from the GE EnerVista CD or
online from http://www.gedigitalenergy.com/multilin). See the Software Installation section if not already installed.
2.
Connect the computer to the F485 and the F485 to the RS485 terminal on the back of the UR device, or connect
directly the computer to the RS232 port on the front of the relay.
3.
Select the "UR" device from the EnerVista Launchpad to start EnerVista UR Setup.
4.
Click the Device Setup button to open the Device Setup window and click the Add Site button to define a new site.
5.
Enter a site name in the "Site Name" field. Optionally add a short description of the site along with the display order of
devices defined for the site. In this example, we use "Location 1" as the site name. Click the OK button when complete.
The new site appears in the upper-left list in the EnerVista UR Setup window.
6.
Click the Device Setup button, then select the new site to re-open the Device Setup window.
7.
Click the Add Device button to define the new device.
8.
Enter a name in the "Device Name" field and a description (optional) of the site.
9.
Select "Serial" from the Interface drop-down list. This displays a number of interface parameters that must be entered
for serial communications.
10. Enter the COM port used by the computer, the baud rate, and parity settings from the front panel

SETUP
COMMUNICATIONS
1-8
Figure 1–4: CONFIGURING SERIAL COMMUNICATIONS
menu, and the relay slave address setting from the front panel
SERIAL PORTS
T35 Transformer Protection System
1 GETTING STARTED
SETTINGS
PRODUCT
SETTINGS
GE Multilin