Level damping (F = 1 s)
Damping of level in s
Value
Set the damping of the level value in seconds. It acts on the analog output, the limit value
monitor and the local display. For damping of the sensor signal, set Function 4.2.3:.
Application Type (F - Liquid [store])
Use of the vessel
Value
Select Silo1 (solids) for tall, narrow silos. Select Silo 2 (solids) for large diameter silos typcially
used for cement. In most cases you set one of the pre-specified applications here. The user
vessels may adopt configurations which deviate from the factory settings. These are designed
for special applications loaded at the factory or by service. the following parameters cannot be
accessed when you set a user vessel: Parameter 4.2.2.2, Parameter 4.2.2.5, Parameter 4.2.2.6,
Parameter 4.2.3.1 and Parameter 4.2.3.5

Additional Parameters

2. Display
2.1: Multi-display (F = level in m
Display of two measured values. Values determined in Parameter 4.5.1.1 (Line 1 Local) and
in Parameter 4.5. 1 .4 (Line 2 Local).
2.2: Level (F = m)
Current level of measured medium (set unit using Length Unit in Auto-Setup).
2.3: Volume (F = m
Volume of measured medium (set unit using Parameter 4.1.2: Volume Unit).
7ML19985FH01
numerical value
Liquid (store)
Liquid (process)
Silo1 (solids)
Silo2 (solids)
User tank1
User tank2
Signal to noise ratio in db)
3
)
SITRANS LR 400 – INSTRUCTION MANUAL DRAFT
Page 27