Frame Earth Connection; 19-Inch Rack Mounting - Panasonic VL-VN1700 Installation Manual

Video intercom system - control box
Hide thumbs Also See for VL-VN1700:
Table of Contents

Advertisement

3.2.3 Frame Earth Connection

3.2.3 Frame Earth Connection
1.
Loosen the screw.
2.
Insert an earthing wire (user-
supplied).
3.
Tighten the screw.
4.
Connect the earthing wire to earth.
WARNING
Proper earthing (connection to earth) is very important to reduce the risk to the user of
electrocution or to protect the unit from the bad effects of external noise in the case of a
lightning strike.
The earthing wire of the AC cable has an effect against external noise and lightning strikes,
but it may not be enough to protect the unit and to ensure electromagnetic compatibility. A
permanent connection between earth and the earth terminal of the unit must be made.
CAUTION
For earthing wire, green-and-yellow insulation is required, and the cross-sectional area of the conductor
must be more than 0.75 mm
Notice
Be sure to comply with applicable local regulations (e.g., laws, guidelines).

3.2.4 19-inch Rack Mounting

WARNING
Be careful not to drop any components. Dropping components may damage them or cause an
injury.
When mounting the unit on a 19-inch rack, only use the 19-inch rack mounting equipment
(attachment bracket, screws) included with the unit.
CAUTION
When the unit is mounted on a 19-inch rack, make sure that the installation of the unit does not cause
the temperature of the rack to exceed its limit.
When the unit is mounted on a 19-inch rack, allow space of at least 5 cm to the sides of unit and at
least 10 cm to the rear of the unit for ventilation of the fan.
30
Installation Manual
A. Screw
B. Earthing wire
(1) To earth
or 18 AWG.
2
A
B
(1)