Ea31 Imager Typical Reading Distances - Intermec CN51 User Manual

For windows embedded handheld 6.5
Hide thumbs Also See for CN51:
Table of Contents

Advertisement

Appendix A — Specifications

EA31 Imager Typical Reading Distances

128
EA31 Minimum Reading Distances
Symbology
Density
Code 39
0.10 mm/4
mils0.13 mm/5
mils0.20 mm/8
mils0.25 mm/10
mils0.50 mm/20
mils1 mm/40
mils
EAN/UPC 100% 0.33 mm/13 mils 5 cm/1.97 in
DataMatrix
0.18 mm/7
mils0.25 mm/10
mils0.38 mm/15
mils
PDF417
0.17 mm/6.6
mils0.25 mm/10
mils0.38 mm/15
mils
Minimum reading distances are measured in the dark (0 lux).
Minimum
Distance
8 cm/3.15 in7
cm/2.76 in4
cm/1.57 in3.8
cm/1.5 in7
cm/2.76 in13.5
cm/5.31 in
7 cm/2.76 in5
cm/1.97 in5.2
cm/2.05 in
5.8 cm/2.28 in4
cm/1.57 in4.9
cm/1.93 in
DRAFT
Maximum Distance
10 cm/3.94 in13
cm/5.12 in20
cm/7.87 in24.5
xm/9.65 in45
cm/17.72 in71.5
cm/28.15 in
29.5 cm/11.61 in
14 cm/5.51 in20
cm/7.87 in29.5
cm/11.61 in
17.5 cm/6.89 in26.5
cm/10.43 in37
cm/14.57 in