Ea30 Area Imager Typical Reading Distances - Intermec CK70 User Manual

70 series
Hide thumbs Also See for CK70:
Table of Contents

Advertisement

Appendix A — Specifications and Default Settings

EA30 Area Imager Typical Reading Distances

Typical distances are measured in an office environment (250 lux).
12"
8"
4"
0"
4"
8"
12"
EA30 Typical Reading Distances
Symbology
Density
Code 39
0.1 mm (4 mils)
0.125 mm (5 mils)
0.5 mm (20 mils)
1 mm (40 mils)
UPC/EAN 100%
0.33 mm (13.0 mils)
Data Matrix
0.18 mm (7 mils)
0.25 mm (10 mils)
0.38 mm (15 mils)
PDF417
0.25 mm (10 mils)
0.38 mm (15 mils)
136
0"
4"
8"
in
Data Matrix 10 mils
PDF417 10 mils
0.125mm/5 mils
EAN/UPC
0.5 mm / 20 mils
0
10
20
12"
16"
20"
24"
1 mm / 40 mils
30
40
50
60
Minimum Distance
9.5 cm (3.74 in)
8 cm (3.15 in)
6.5 cm (2.56 in)
9.5 cm (3.74 in)
6 cm (2.36 in)
7.5 cm (2.95 in)
6 cm (2.36 in)
5.5 cm (2.17 in)
5.5 cm (2.17 in)
6.5 cm (2.56 in)
70 Series Mobile Computer User Manual
28"
32"
36"
30
20
10
0
10
20
30
cm
70
80
90
Maximum Distance
11.5 cm (4.53 in)
14.5 cm (5.71 in)
50 cm (19.69 in)
75 cm (29.53 in)
34 cm (13.39 in)
16.5 cm (6.5 in)
23 cm (9.06 in)
34.5 cm (13.58 in)
26 cm (10.24 in)
37 cm (14.57 in)